DAF 95XF. Manual - part 355

 

  Index      DAF     DAF 95XF Series - service repair manual

 

Search            

 

 

 

 

 

 

 

 

 

Content   ..  353  354  355  356   ..

 

 

DAF 95XF. Manual - part 355

 

 

5

MODIFICATIONS TO THE ELECTRICAL INSTALLATION

Modifications to the electrical installation from chassis number 0E477514

4-32

40A

1316630/24-29

EL000356

1

23456789

1

0

1

1

1

2

1

3

1

4

1

5

1

6

1

7

1

8

1

9

2

0

2

1

2

2

2

3

2

4

2

5

2

6

2

7

2

8

2

9

3

0

3

1

3

2

3

3

3

4

3

5

3

6

3

7

3

8

3

9

4

0

4

1

4

2

4

3

4

4

4

5

4

6

4

7

4

8

4

9

5

0

5

1

5

2

5

3

1156

1156

1156

4939

9003

4941

5117

1156

3037

3037

3462

3462

3462

4936

4936

4936

4660

4660

4660

4660

1156

4935

4935

12/

269

3/

269

10/

269

14/

269

2/

269

E566

7/

269

11/

269

D871

5/

482

4/

482

12/

482

3/

482

7/

482

13/

482

8/

482

14/

482

11/

482

D878

1010

1000

1010

1000

E114

15A

12

483

34/402

1

483

11

483

6

483

31

115

4

483

7

397

15

380

C778

5

71

0I

5

380

1156

30

115

5

483

A021

14

B122

M

2

1

D703

2

D704

2

D705

2

!

!

!

11

ǹ 0209

5

Modifications to the electrical installation from chassis number 0E477514

MODIFICATIONS TO THE ELECTRICAL INSTALLATION

4-33

40B. AUXILIARY HEATING EBERSPÄCHER (with timer)

The auxiliary air heating is a separate heating
which functions entirely independent of the
vehicle. The cab temperature is measured by a
temperature sensor (F509). This sensor sends a
signal to the electronic unit D871 which controls
the heating.
As a result, the cab temperature automatically
remains at the preset temperature. In that case,
the blower is in continuous operation.

OPERATION OF AUXILIARY HEATING
The auxiliary air heating can be activated using
switch C844. A green lamp in the timer unit will
light up if the system is activated by means of
this switch.
If the heating is activated, it activates the fan in
the heating unit.
At the same time the fuel metering pump for the
auxiliary Eberspächer heating (B122) is
activated, so that the correct amount of fuel is
fed to the ignition chamber of the heating unit.
If the fuel is ignited, the temperature sensor
(F509) will apply a voltage to electronic unit
D871 through wire 4941 so that at a certain
temperature, the heating unit (D871) switches
off.

If the sensor measures a lower temperature
than the temperature preset by the driver (using
the temperature control button on the timer unit),
the heating power will be adjusted.

In the case of overheating, the thermal
protection will switch off the fuel pump. This will
switch off the heating.

11

ǹ 0209

5

MODIFICATIONS TO THE ELECTRICAL INSTALLATION

Modifications to the electrical installation from chassis number 0E477514

4-34

40B

1316630/24-29

EL000363

1

23456789

1

0

1

1

1

2

1

3

1

4

1

5

1

6

1

7

1

8

1

9

2

0

2

1

2

2

2

3

2

4

2

5

2

6

2

7

2

8

2

9

3

0

3

1

3

2

3

3

3

4

3

5

3

6

3

7

3

8

3

9

4

0

4

1

4

2

4

3

4

4

4

5

4

6

4

7

4

8

4

9

5

0

5

1

5

2

5

3

1156

1156

1156

1156

1156

4939

9003

9003

9003

5117

1156

1156

3037

3037

4936

4936

4941

4941

4936

4660

4660

4660

4660

4660

4935

4935

6/

269

4/

269

9/

269

2/

269

E581

7/

269

10/

269

11/

269

12/

269

D871

5/

482

4/

482

3/

482

7/

482

8/

482

13/

482

14/

482

11/

482

D878

1010

1000

1010

1000

E114

15A

12

483

34/402

1

483

11

483

6

483

31

115

4

483

15

380

21

380

30

115

5

483

A021

14

B122

M

2

1

2

1

F509

7

397

C844

4

I0

28

11

ǹ 0209

5

Modifications to the electrical installation from chassis number 0E477514

MODIFICATIONS TO THE ELECTRICAL INSTALLATION

4-35

42. CONNECTOR SOCKETS FT, DIAGNOSTIC CONNECTOR, ALARM

CONNECTOR

DIAGNOSTIC CONNECTOR (A021)
The diagnostic connector is installed on the
left--hand side in the central cabinet. This is the
connector to which DAVIE is connected. After
the contact has been activated, the supply
voltage for DAVIE is applied to pin 1 through
fuse E053. Pin 2 is connected to earth. The
remaining pins are meant for the communication
with various systems and are connected to
those systems.

Pin no.

Wire no.

Colour

Description

1

1229

red

Supply for DAVIE

2

9107

white

Earth

3

3425

blue

ABS/ASC-D

4

4788

black

ASL-G

5

4697

black

ECAS remote control, E-gas 3

6
7

4732

black

ECAS 2

8
9

4047

black

CTE-3

10
11

4883

black

ZF intarder

12
13

3470

blue

AGS

14

3037

blue

D3LC auxiliary heating

15
16

ABS CONNECTOR (A005)
This ABS connector is located at the rear of the
cab.
Pin 1

of the ABS connector (A005) is
connected directly to the supply
voltage through wire 1119 and fuse
E043.

Pin 2

is connected directly to the supply
voltage after contact through fuse
E040. This voltage also serves to feed
the ABS unit.

Pins 3, 4 are both connected to earth.
Pin 5

is connected to pin 7 of the CWS--2
unit (D582) through wire 3428.

11

ǹ 0209

 

 

 

 

 

 

 

Content   ..  353  354  355  356   ..