Symptom: OVERHEAD LIFTGATE/LOCKOUT SWITCHES OPEN OR SHT TO When Monitored and Set Condition: OVERHEAD LIFTGATE/LOCKOUT SWITCHES OPEN OR SHT TO VOLTAGE When Monitored: Whenever the BCM is awake. Set Condition: When the BCM senses a overhead liftgate switch input that is greater than 4.8 volts for over 10 seconds, this code will set. POSSIBLE CAUSES DTC PRESENT SLIDING DOORS OVERHEAD SWITCH MUX CIRCUIT SHORT TO VOLTAGE LIFTGATE SWITCH MUX WIRE OPEN BODY CONTROL MODULE - OVERHEAD SWITCH OPEN OVERHEAD SWITCH OPEN LIFTGATE SWITCH MUX SHORT TO VOLTAGE POWER SLIDING DOOR BUTTON MODULE - SHORT TO VOLTAGE TEST ACTION APPLICABILITY 1 With the DRBIII t, record and erase DTC’s. Turn the ignition off, wait 10 seconds, then turn the ignition on. t, read DTCs. Does the DRBIII t display OVERHEAD LIFTGATE/LOCKOUT SWITCHES OPEN OR SHT TO VOLTAGE? All Yes → Go To 2 No → Using the wiring diagram/schematic as a guide, inspect the wiring and connectors for an intermittent condition. 2 Disconnect the Body Control Module C3 connector. All Yes → Repair the Sliding Doors Overhead Switch Mux circuit for a short to voltage. No → Go To 3 852 POWER DOORS - LIFTGATE |