Chrysler Town, Dodge Caravan. Manual - part 767

 

  Index      Chrysler     Chrysler TOWN & COUNTRY, VOYAGER, Dodge Caravan - service repair manual 2001-2007 year

 

Search            

 

 

 

 

 

 

 

 

 

Content   ..  765  766  767  768   ..

 

 

Chrysler Town, Dodge Caravan. Manual - part 767

 

 

TEST

ACTION

APPLICABILITY

4

WARNING: DO NOT OPERATE THE DCHA IN AN ENCLOSED AREA SUCH
AS A GARAGE THAT DOES NOT HAVE EXHAUST VENTILATION FACILI-
TIES. ALWAYS VENT THE DCHA’s EXHAUST WHEN OPERATING THE
DCHA. FAILURE TO FOLLOW THESE INSTRUCTIONS MAY RESULT IN
PERSONAL INJURY OR DEATH.
WARNING: ALLOW THE DCHA ASSEMBLY TO COOL BEFORE PERFORM-
ING A COMPONENT INSPECTION/REPAIR/REPLACEMENT. FAILURE TO
FOLLOW THESE INSTRUCTIONS MAY RESULT IN PERSONAL INJURY.
Turn the ignition off.
NOTE: Check connectors - Clean/repair as necessary.
Disconnect the Dosing Pump harness connector.
Disconnect the Dosing Pump rubber insulators from the splash shield.
Measure the resistance of the Dosing Pump.
Is the resistance between 3.0 and 10.0 ohms?

All

Yes

→ Replace the DCHA Heater Module in accordance with the Service

Information.
Perform CABIN HEATER VERIFICATION TEST - VER 1.

No

→ Replace the Dosing Pump in accordance with the Service Infor-

mation.
Perform CABIN HEATER VERIFICATION TEST - VER 1.

304

CABIN HEATER

B1820 DOSING PUMP CIRCUIT: OPEN OR SHORT TO BATTERY —

Continued

Symptom:

B1820 DOSING PUMP CIRCUIT: SHORT TO GROUND

When Monitored and Set Condition:

B1820 DOSING PUMP CIRCUIT: SHORT TO GROUND

When Monitored:

During Dosing Pump activation.

Set Condition:

This DTC will set if the DCHA Control detects a high current draw on the

Dosing Pump circuit output pin.

POSSIBLE CAUSES

DOSING PUMP SHORTED TO GROUND

DOSING PUMP CONTROL CIRCUIT SHORTED TO THE GROUND CIRCUIT

DOSING PUMP CONTROL CIRCUIT SHORTED TO GROUND

DCHA CONTROL UNIT FAULT

305

CABIN HEATER

TEST

ACTION

APPLICABILITY

1

WARNING: DO NOT OPERATE THE DCHA IN AN ENCLOSED AREA SUCH
AS A GARAGE THAT DOES NOT HAVE EXHAUST VENTILATION FACILI-
TIES. ALWAYS VENT THE DCHA’s EXHAUST WHEN OPERATING THE
DCHA. FAILURE TO FOLLOW THESE INSTRUCTIONS MAY RESULT IN
PERSONAL INJURY OR DEATH.
WARNING: ALLOW THE DCHA ASSEMBLY TO COOL BEFORE PERFORM-
ING A COMPONENT INSPECTION/REPAIR/REPLACEMENT. FAILURE TO
FOLLOW THESE INSTRUCTIONS MAY RESULT IN PERSONAL INJURY.
CAUTION: DO NOT PERFORM THIS TEST UNLESS DIRECTED HERE BY
THE CABIN HEATER PRE-TEST. ALWAYS PERFORM THE CABIN HEATER
PRE-TEST PRIOR TO PERFORMING ANY OTHER CABIN HEATER TEST
FOR THE RESULT TO BE VALID.
NOTE: If present, diagnose and repair DTC B1811 Heater Overheated and
any other conditions relating to overheating before diagnosing this DTC.
Turn the ignition off.
NOTE: Check connectors - Clean/repair as necessary.
Disconnect the Dosing Pump harness connector.
Turn the ignition on.
On MTC, set the Blend control to the max cool position.
On ATC, set the Driver temperature control to LO (max cool).
Turn the ATC’s or MTC’s Power switch off.
With the DRBIII

t, erase Cabin Heater DTCs.

Start the engine.
Allow the engine to idle.
Turn the ATC’s or MTC’s Power switch on.
Turn the Blower control to the high speed position.
CAUTION: Do not activate the DCHA Field Mode Test with the engine off.
Failure to follow these instructions may result in internal damage to the
DCHA Heater Module.
NOTE: Do not disconnect the vehicle’s battery or the DCHA’s main power
supply while the DCHA is in operation or in run-down mode. Failure to
follow these instructions may result in excess emissions from the DCHA
during heater operation.
With the DRBIII

t in Cabin Heater, Systems Tests, select Field Mode and press Enter.

The test will run for approx 8.5 minutes.
On MTC, set the Blend control to the max heat position. Upon completion of the Field
Mode Test, proceed as follows:
On ATC, set the Driver temperature control to HI (max heat). Upon completion of the
Field Mode Test, proceed as follows:
With the DRBIII

t, read Cabin Heater DTCs.

Turn the Blower control off and turn the ATC’s or MTC’s Power switch off.
Turn the engine off.
Is DTC B1820 Dosing Pump Circuit: Short to Ground present?

All

Yes

→ Go To 2

No

→ Replace the Dosing Pump in accordance with the Service Infor-

mation.
Perform CABIN HEATER VERIFICATION TEST - VER 1.

306

CABIN HEATER

B1820 DOSING PUMP CIRCUIT: SHORT TO GROUND —

Continued

TEST

ACTION

APPLICABILITY

2

WARNING: DO NOT OPERATE THE DCHA IN AN ENCLOSED AREA SUCH
AS A GARAGE THAT DOES NOT HAVE EXHAUST VENTILATION FACILI-
TIES. ALWAYS VENT THE DCHA’s EXHAUST WHEN OPERATING THE
DCHA. FAILURE TO FOLLOW THESE INSTRUCTIONS MAY RESULT IN
PERSONAL INJURY OR DEATH.
CAUTION: ALLOW THE DCHA ASSEMBLY TO COOL BEFORE PERFORM-
ING A COMPONENT INSPECTION/REPAIR/REPLACEMENT. FAILURE TO
FOLLOW THESE INSTRUCTIONS MAY RESULT IN PERSONAL INJURY.
Turn the ignition off.
Disconnect the battery in accordance with the Service information.
NOTE: Check connectors - Clean/repair as necessary.
Disconnect the Dosing Pump harness connector.
NOTE: Check connectors - Clean/repair as necessary.
Disconnect the Cabin Heater Assist C1 and C2 harness connectors.
Measure the resistance between the Dosing Pump Control circuit and the Ground
circuit.
Is the resistance below 10K ohms?

All

Yes

→ Repair the Dosing Pump Control circuit for a short to the Ground

circuit.
Perform CABIN HEATER VERIFICATION TEST - VER 1.

No

→ Go To 3

3

WARNING: DO NOT OPERATE THE DCHA IN AN ENCLOSED AREA SUCH
AS A GARAGE THAT DOES NOT HAVE EXHAUST VENTILATION FACILI-
TIES. ALWAYS VENT THE DCHA’s EXHAUST WHEN OPERATING THE
DCHA. FAILURE TO FOLLOW THESE INSTRUCTIONS MAY RESULT IN
PERSONAL INJURY OR DEATH.
WARNING: ALLOW THE DCHA ASSEMBLY TO COOL BEFORE PERFORM-
ING A COMPONENT INSPECTION/REPAIR/REPLACEMENT. FAILURE TO
FOLLOW THESE INSTRUCTIONS MAY RESULT IN PERSONAL INJURY.
Turn the ignition off.
Disconnect the battery in accordance with the Service information.
NOTE: Check connectors - Clean/repair as necessary.
Disconnect the Dosing Pump harness connector.
NOTE: Check connectors - Clean/repair as necessary.
Disconnect the Cabin Heater Assist C1 harness connector.
Measure the resistance between ground and the Dosing Pump Control circuit.
Is the resistance below 10K ohms?

All

Yes

→ Repair the Dosing Pump Control circuit for a short to ground.

Perform CABIN HEATER VERIFICATION TEST - VER 1.

No

→ Replace the DCHA Heater Module in accordance with the Service

Information.
Perform CABIN HEATER VERIFICATION TEST - VER 1.

307

CABIN HEATER

B1820 DOSING PUMP CIRCUIT: SHORT TO GROUND —

Continued

 

 

 

 

 

 

 

Content   ..  765  766  767  768   ..