Chrysler Town, Dodge Caravan. Manual - part 1148

 

  Index      Chrysler     Chrysler TOWN & COUNTRY, VOYAGER, Dodge Caravan - service repair manual 2001-2007 year

 

Search            

 

 

 

 

 

 

 

 

 

Content   ..  1146  1147  1148  1149   ..

 

 

Chrysler Town, Dodge Caravan. Manual - part 1148

 

 

Symptom List:

P0620-GENERATOR FIELD CONTROL MALF BATTERY VOLTAGE
TOO HIGH
P0620-GENERATOR FIELD CONTROL MALF SHORT CIRCUIT
P0620-GENERATOR FIELD CONTROL MALF UNSTABLE CUR-
RENT

Test Note:

All symptoms listed above are diagnosed using the same tests.

The title for the tests will be P0620-GENERATOR FIELD
CONTROL MALF BATTERY VOLTAGE TOO HIGH.

When Monitored and Set Condition:

P0620-GENERATOR FIELD CONTROL MALF BATTERY VOLTAGE TOO HIGH

When Monitored:

With the engine running.

Set Condition:

The ECM senses battery voltage above 16.5 volts.

P0620-GENERATOR FIELD CONTROL MALF SHORT CIRCUIT

When Monitored:

With the ignition on and the ECM attempting to actuate the Generator

Field.

Set Condition:

The ECM detects excessive current on the Generator Field Control circuit

when attempting to actuate the Generator Field.

POSSIBLE CAUSES

INTERMITTENT CONDITION

GENERATOR FIELD

GENERATOR FIELD CONTROL CIRCUIT SHORTED TO VOLTAGE

GENERATOR FIELD CONTROL CIRCUIT SHORTED TO GROUND

GENERATOR FIELD CONTROL CIRCUIT OPEN

HIGH RESISTANCE ON THE ECM/PCM RELAY OUTPUT CIRCUIT

HIGH RESISTANCE ON THE GROUND CIRCUIT

ENGINE CONTROL MODULE

135

DRIVEABILITY - DIESEL

TEST

ACTION

APPLICABILITY

1

NOTE: If the ECM detects and stores a DTC, the ECM also stores the
engine/vehicle operating conditions under which the DTC was set. Some of
these conditions are displayed on the DRB at the same time the DTC is
displayed.
NOTE: Before erasing stored DTCs, record these conditions. Attempting to
duplicate these conditions may assist when checking for an active DTC.
Turn the ignition on.
With the DRB, erase ECM DTCs.
Start the engine several times. Allow the engine to run for at least 30 seconds at more
than 1200 RPM each run cycle while turning the ignition off for at least 10 seconds
between each run cycle.
Monitor the DRB for ECM DTCs.
Did this DTC set again?

All

Yes

→ Go To 2

No

→ Go To 9

2

Turn the ignition off.
Disconnect the Generator Field harness connector.
Measure the resistance of the Field Control terminals on the back of the Generator.
Is the resistance between 2 and 6 ohms?

All

Yes

→ Go To 3

No

→ Repair or replace the Generator as necessary.

Perform CHARGING VERIFICATION - VER-3.

3

Turn the ignition off.
Disconnect the ECM harness connectors.
Disconnect the Generator Field harness connector.
Remove the ECM/PCM Relay from the IPM.
Connect a jumper wire between cavity 30 and cavity 87 of the ECM/PCM Relay
connector.
Turn the ignition on.
Measure the voltage of the Generator Field Control circuit.
Is the voltage below 1.0 volt?

All

Yes

→ Go To 4

No

→ Repair the Generator Field Control circuit for a short to voltage.

Perform CHARGING VERIFICATION - VER-3.

4

Turn the ignition off.
Disconnect ECM harness connectors.
Disconnect the Generator Field harness connector.
Measure the resistance between ground and the Generator Field Control circuit.
Is the resistance above 1000 ohms?

All

Yes

→ Go To 5

No

→ Repair the Generator Field Control circuit for a short to ground.

Perform CHARGING VERIFICATION - VER-3.

136

DRIVEABILITY - DIESEL

P0620-GENERATOR FIELD CONTROL MALF BATTERY VOLTAGE TOO
HIGH —

Continued

TEST

ACTION

APPLICABILITY

5

Turn the ignition off.
Disconnect the ECM harness connectors.
Disconnect the Generator Field harness connector.
Measure the resistance of the Generator Field Control circuit.
Is the resistance below 5.0 ohms?

All

Yes

→ Go To 6

No

→ Repair the Generator Field Control circuit for an open.

Perform CHARGING VERIFICATION - VER-3.

6

Turn the ignition off.
Disconnect the ECM harness connectors.
Remove the ECM/PCM Relay from the IPM.
Measure the resistance of the ECM/PCM Relay Output circuit between the ECM/
PCM Relay connector and ECM harness connector cavity C1-19.
Is the resistance below 5.0 ohms?

All

Yes

→ Go To 7

No

→ Repair the ECM/PCM Relay Output circuit for high resistance.

Perform CHARGING VERIFICATION - VER-3.

7

Turn the ignition off.
Disconnect the ECM harness connectors.
Measure the resistance of the Ground circuit at ECM harness connector cavity C1-20.
Is the resistance below 5.0 ohms?

All

Yes

→ Go To 8

No

→ Repair the Ground circuit for high resistance.

Perform CHARGING VERIFICATION - VER-3.

8

If there are no possible causes remaining, view repair.

All

Repair

Replace and program the Engine Control Module in accordance
with the Service Information.
Perform CHARGING VERIFICATION - VER-3.

9

WARNING: WHEN THE ENGINE IS OPERATING, DO NOT STAND IN A
DIRECT LINE WITH THE FAN. DO NOT PUT YOUR HANDS NEAR THE
PULLEYS, BELTS OR FAN. DO NOT WEAR LOOSE CLOTHING.
NOTE: The conditions that set the DTC are not present at this time. The
following list may help in identifying the intermittent condition.
With the engine running at normal operating temperature and at more than 1200
RPM, monitor the DRB parameters related to the DTC while wiggling the wiring
harness. Look for parameter values to change and/or a DTC to set.
Review the DTC When Monitored and Set Conditions. If possible, try to duplicate the
conditions under which the DTC was set.
Refer to any Technical Service Bulletins (TSB) that may apply.
Visually inspect the related wiring harness. Look for any chafed, pierced, pinched, or
partially broken wires.
Visually inspect the related wiring harness connectors. Look for broken, bent, pushed
out, or corroded terminals.
Were any of the above conditions present?

All

Yes

→ Repair as necessary

Perform CHARGING VERIFICATION - VER-3.

No

→ Test Complete.

137

DRIVEABILITY - DIESEL

P0620-GENERATOR FIELD CONTROL MALF BATTERY VOLTAGE TOO
HIGH —

Continued

Symptom:

P0627-FUEL LIFT PUMP RELAY CONTROL CIRCUIT OPEN CIR-
CUIT

POSSIBLE CAUSES

INTERMITTENT CONDITION

IGNITION SWITCH (RUN/START) CIRCUIT OPEN

FUEL LIFT PUMP RELAY

FUEL LIFT PUMP RELAY CONTROL CIRCUIT SHORTED TO GROUND

FUEL LIFT PUMP RELAY CONTROL CIRCUIT OPEN

ENGINE CONTROL MODULE

TEST

ACTION

APPLICABILITY

1

NOTE: If the ECM detects and stores a DTC, the ECM also stores the
engine/vehicle operating conditions under which the DTC was set. Some of
these conditions are displayed on the DRB at the same time the DTC is
displayed.
NOTE: Before erasing stored DTCs, record these conditions. Attempting to
duplicate these conditions may assist when checking for an active DTC.
Turn the ignition on.
With the DRB, actuate the Fuel Lift Pump Relay.
Does the Fuel Lift Pump Relay cycle on and off?

All

Yes

→ Go To 2

No

→ Go To 3

2

WARNING: WHEN THE ENGINE IS OPERATING, DO NOT STAND IN A
DIRECT LINE WITH THE FAN. DO NOT PUT YOUR HANDS NEAR THE
PULLEYS, BELTS OR FAN. DO NOT WEAR LOOSE CLOTHING.
NOTE: The conditions that set the DTC are not present at this time. The
following list may help in identifying the intermittent condition.
With the engine running at normal operating temperature, monitor the DRB
parameters related to the DTC while wiggling the wiring harness. Look for param-
eter values to change and/or a DTC to set.
Review the DTC When Monitored and Set Conditions. If possible, try to duplicate the
conditions under which the DTC was set.
Refer to any Technical Service Bulletins (TSB) that may apply.
Visually inspect the related wiring harness. Look for any chafed, pierced, pinched, or
partially broken wires.
Visually inspect the related wiring harness connectors. Look for broken, bent, pushed
out, or corroded terminals.
Were any of the above conditions present?

All

Yes

→ Repair as necessary.

Perform ROAD TEST VERIFICATION - VER-2.

No

→ Test Complete.

138

DRIVEABILITY - DIESEL

 

 

 

 

 

 

 