4. CHECK THE (C255) LEFT BLEND DOOR DRIVER CIRCUIT FOR A SHORT TO THE (C268) Measure the resistance between the (C255) Left Blend Door Driver cir- Is the resistance below 10k ohms on any of the circuits? Yes >> Repair all circuits with a resistance below 10k ohms for a short to the (C255) Left Blend Door Driver circuit. Perform BODY VERIFICATION TEST – VER 1. (Refer to 8 ELECTRICAL/ELECTRONIC CONTROL MODULES/ FRONT CONTROL MODULE - DIAGNOSIS AND TEST- No >> Go To 5 5. CHECK THE (C55) LEFT BLEND DOOR COMMON DRIVER CIRCUIT FOR A SHORT TO THE (C268) Measure the resistance between the (C55) Left Blend Door Common Is the resistance below 10k ohms on any of the circuits? Yes >> Repair all circuits with a resistance below 10k ohms for a short to the (C55) Left Blend Door Common Driver circuit. Perform BODY VERIFICATION TEST – VER 1. (Refer to 8 ELECTRICAL/ELECTRONIC CONTROL MODULES/ FRONT CONTROL MODULE - DIAGNOSIS AND TEST- No >> Go To 6 24 - 50 HVAC - ELECTRICAL DIAGNOSTICS LX |