Chery Tiggo 5 (T21). Manual - part 423

 

  Index      Chery     Chery Tiggo 5 (T21) - service repair manual 2014 year

 

Search            

 

 

 

 

 

 

 

 

 

Content   ..  421  422  423  424   ..

 

 

Chery Tiggo 5 (T21). Manual - part 423

 

 

37–

31

37

g. Disconnect the body wire harness connectors B-047 and 

B-026.

h. Using a digital multimeter, check for continuity between 

body wire harness connectors B-047 and B-026 
according to the table below.

i. Disconnect the body wire harness connectors B-047 and 

B-005.

j. Using a digital multimeter, check for continuity between 

body wire harness connectors B-047 and B-005 
according to the table below.

k. Disconnect the body wire harness connectors B-040 and 

B-043.

l. Using a digital multimeter, check for continuity between 

body wire harness connectors B-040 and B-043 
according to the table below.

-

+

RT21370520

B1 B2 B3 B4 B5 B6 B7 B8 B9 B10 B11 B12 B13 B14 B15 B16

B17 B18 B19 B20 B21 B22 B23 B24 B25 B26 B27 B28 B29 B30 B31 B32

B-047

1

2

7

13

14

8

3

9

4

10

11

12

15

16

5

6

B-026

Multimeter 

Connection 

Terminal

Condition

Specified 

Condition

B-047 (B21) - 

B-026 (16)

Always

Continuity

-

+

RT21370530

B1 B2 B3 B4 B5 B6 B7 B8 B9 B10 B11 B12 B13 B14 B15 B16

B17 B18 B19 B20 B21 B22 B23 B24 B25 B26 B27 B28 B29 B30 B31 B32

B-047

1

2

7

8

13

14

3

4

9

10

5

6

11

12

15

16

B-005

Multimeter 

Connection 

Terminal

Condition

Specified 

Condition

B-047 (B4) - 

B-005 (16)

Always

Continuity

-

+

RT21370540

1

4

7 10 13 16

2

5

8 11 14 17

3

6

9 12 15 18

B-040

C1

C10 C11 C12 C13 C14 C15 C16 C17 C18

C2 C3 C4 C5

C6 C7 C8 C9

C20

C19

B-043

Multimeter 

Connection 

Terminal

Condition

Specified 

Condition

B-040 (5) - B-043 

(C20)

Always

Continuity

37–

32

37

m. Disconnect the body wire harness connectors B-043 and 

B-061.

n. Using a digital multimeter, check for continuity between 

body wire harness connectors B-043 and B-061 
according to the table below.

o. Disconnect the body wire harness connectors B-043 and 

B-026.

p. Using a digital multimeter, check for continuity between 

body wire harness connectors B-043 and B-026 
according to the table below.

q. Disconnect the body wire harness connectors B-043 and 

B-005.

r. Using a digital multimeter, check for continuity between 

body wire harness connectors B-043 and B-005 
according to the table below.

-

+

RT21370550

1

4

7 10 13 16

2

5

8 11 14 17

3

6

9 12 15 18

B-061

C1

C10 C11 C12 C13 C14 C15 C16 C17 C18

C2 C3 C4 C5

C6 C7 C8 C9

C20

C19

B-043

Multimeter 

Connection 

Terminal

Condition

Specified 

Condition

B-043 (C19) - 

B-061(5) 

Always

Continuity

B-043 (C20) - 

B-061 (4) 

Always

Continuity

-

+

RT21370560

C1

C10 C11 C12 C13 C14 C15 C16 C17 C18

C2 C3 C4 C5

C6 C7 C8 C9

C20

C19

B-043

1

2

7

13

14

8

3

9

4

10

11

12

15

16

5

6

B-026

Multimeter 

Connection 

Terminal

Condition

Specified 

Condition

B-043 (C19) - 

B-026 (1) 

Always

Continuity

B-043 (C20) - 

B-026 (2) 

Always

Continuity

-

+

RT21370570

C1

C10 C11 C12 C13 C14 C15 C16 C17 C18

C2 C3 C4 C5

C6 C7 C8 C9

C20

C19

B-043

1

2

7

8

13

14

3

4

9

10

5

6

11

12

15

16

B-005

Multimeter 

Connection 

Terminal

Condition

Specified 

Condition

B-043 (C19) - 

B-005 (1) 

Always

Continuity

B-043 (C20) - 

B-005 (2) 

Always

Continuity

37–

33

37

s. Disconnect the body wire harness connectors B-040 and 

B-061.

t. Using a digital multimeter, check for continuity between 

body wire harness connectors B-040 and B-061 
according to the table below.

u. Disconnect the body wire harness connectors B-040 and 

B-026.

v. Using a digital multimeter, check for continuity between 

body wire harness connectors B-040 and B-026 
according to the table below.

w. Disconnect the body wire harness connectors B-040 and 

B-005.

x. Using a digital multimeter, check for continuity between 

body wire harness connectors B-040 and B-005 
according to the table below.

-

+

RT21370580

1

4

7 10 13 16

2

5

8 11 14 17

3

6

9 12 15 18

B-040

1

4

7 10 13 16

2

5

8 11 14 17

3

6

9 12 15 18

B-061

Multimeter 

Connection 

Terminal

Condition

Specified 

Condition

B-040 (7) - B-061 

(5) 

Always

Continuity

-

+

RT21370590

1

4

7 10 13 16

2

5

8 11 14 17

3

6

9 12 15 18

B-040

1

2

7

13

14

8

3

9

4

10

11

12

15

16

5

6

B-026

Multimeter 

Connection 

Terminal

Condition

Specified 

Condition

B-040 (7) - B-026 

(1) 

Always

Continuity

-

+

RT21370600

1

4

7 10 13 16

2

5

8 11 14 17

3

6

9 12 15 18

B-040

1

2

7

8

13

14

3

4

9

10

5

6

11

12

15

16

B-005

Multimeter 

Connection 

Terminal

Condition

Specified 

Condition

B-040 (7) - B-005 

(1) 

Always

Continuity

37–

34

37

y. Disconnect the body wire harness connector B-040 and 

ground B-036.

z. Using a digital multimeter, check for continuity between 

body wire harness connector B-040 and B-036 according 
to the table below.

aa.Disconnect the body wire harness connector B-061 and 

ground B-062.

ab.Using a digital multimeter, check for continuity between 

body wire harness connector B-061 and B-062 according 
to the table below.

ac.Disconnect the body wire harness connector B-026 and 

ground B-036.

ad.Using a digital multimeter, check for continuity between 

body wire harness connector B-026 and B-036 according 
to the table below.

-

+

RT21370610

1

4

7 10 13 16

2

5

8 11 14 17

3

6

9 12 15 18

B-040

B-036

Multimeter 

Connection 

Terminal

Condition

Specified 

Condition

B-040 (3) - B-036

Always

Continuity

-

+

RT21370620

1

4

7 10 13 16

2

5

8 11 14 17

3

6

9 12 15 18

B-061

B-062

Multimeter 

Connection 

Terminal

Condition

Specified 

Condition

B-061 (3) - B-062

Always

Continuity

-

+

RT21370630

1

2

7

13

14

8

3

9

4

10

11

12

15

16

5

6

B-026

B-036

Multimeter 

Connection 

Terminal

Condition

Specified 

Condition

B-026 (5) - B-036

Always

Continuity

 

 

 

 

 

 

 

Content   ..  421  422  423  424   ..