|
|
37– 31 37 g. Disconnect the body wire harness connectors B-047 and B-026. h. Using a digital multimeter, check for continuity between body wire harness connectors B-047 and B-026 i. Disconnect the body wire harness connectors B-047 and B-005. j. Using a digital multimeter, check for continuity between body wire harness connectors B-047 and B-005 k. Disconnect the body wire harness connectors B-040 and B-043. l. Using a digital multimeter, check for continuity between body wire harness connectors B-040 and B-043 - + RT21370520 B1 B2 B3 B4 B5 B6 B7 B8 B9 B10 B11 B12 B13 B14 B15 B16 B17 B18 B19 B20 B21 B22 B23 B24 B25 B26 B27 B28 B29 B30 B31 B32 B-047 1 2 7 13 14 8 3 9 4 10 11 12 15 16 5 6 B-026 Multimeter Connection Terminal Condition Specified Condition B-047 (B21) - B-026 (16) Always Continuity - + RT21370530 B1 B2 B3 B4 B5 B6 B7 B8 B9 B10 B11 B12 B13 B14 B15 B16 B17 B18 B19 B20 B21 B22 B23 B24 B25 B26 B27 B28 B29 B30 B31 B32 B-047 1 2 7 8 13 14 3 4 9 10 5 6 11 12 15 16 B-005 Multimeter Connection Terminal Condition Specified Condition B-047 (B4) - B-005 (16) Always Continuity - + RT21370540 1 4 7 10 13 16 2 5 8 11 14 17 3 6 9 12 15 18 B-040 C1 C10 C11 C12 C13 C14 C15 C16 C17 C18 C2 C3 C4 C5 C6 C7 C8 C9 C20 C19 B-043 Multimeter Connection Terminal Condition Specified Condition B-040 (5) - B-043 (C20) Always Continuity |