4. REFERENCE POSITION ESTABLISHMENT
B-64693EN-1/01
- 778 - (In case of the linear scale with distance-coded reference marks (serial), it is not <2> Position the machine at the reference position by manual operation. Alarm PS5220, “REFERENCE POINT ADJUSTMENT MODE”, occurs. <4> Perform a manual reference position return operation. Upon completion of manual reference position return operation, parameters Nos. 1883 and 1884 are set, and this
1883
Distance 1 from the base point to reference position
NOTE
When this parameter is set, the power must be turned off before
[Input type] Parameter input
[Data type] 2-word axis
[Unit of data] Detection unit [Valid data range] -999999999 to 999999999
1884
Distance 2 from the base point to reference position
NOTE
When this parameter is set, the power must be turned off before
[Input type] Parameter input
[Data type] 2-word axis
[Unit of data] Detection unit [Valid data range] -999 to 999 Set the distance from the base point to the reference position in parameter Nos. 1883 and
Mark 1
Mark 2 Mark 1
Mark 2 Mark 1
Mark 1
Mark 2
Reference position
10.020 9.980 10.040 9.960 10.060 9.940 Base point 20.000 20.020
Fig. 4.9 (a) |