01-198
Display group 6 - Basic function Engine running at idle Read measured value
Indicated on display
xxxx xxx.x % xxx.x C xx.x %
1 2 3 4 Display zones Specification Evaluation
Elevation -50.0...20.0 % ---
Intake air temperature -37.0...126.0 C
Page 01- 196
Engine load 12.0...26.0 %
Page 01- 201
Engine speed (idle speed) 640...720 rpm
Page 01- 188
Note on display zone 2: The engine load at idling is given as the specification. Note on display zone 3: The total temperature range is given as the specification. The displayed value must be Measured value (data) blocks |