IGNITION AND INJECTION 17 17 - 34 UPSTREAM OXYGEN SENSOR HEATING CIRCUIT DF018 PRESENT OR MEMORIZED Conditions for diagnostic application for memorized failure: * If the failure is memorized with OBD indicator on, check in the context part, ndicator lighting request is affirmative. In this case, proceed as per bellow mentioned RECOMMENDATIONS Perform the operations from “recommendations” for reparation confirmation. AFTER REPARATION Diagnostic – Failures interpretation Check the connection and the connector state of the oxygen sensor. Check the heating resistance of the oxygen sensor. Refer to chapter ”Help” for resistance values. Check the presence of +12 Volts on A way of the oxygen s ensor. Fix the electric connection between A way oxygen sensor and the actuators relay. Connect the 90 ways terminal box instead of the injection computer then check the insulation, the Pin 63 injection computer > pin B oxygen sensor Fix if necessary. If the problem is persisting after these checking, fix the other failures then perform the conformity |