SERVICE INFORMATION FOR ELECTRICAL INCIDENT GI-49 < BASIC INSPECTION > C D E F G H I J K L M B GI N O P INPUT-OUTPUT VOLTAGE CHART • The voltage value is based on the body ground. • *: If high resistance exists in the switch side circuit (caused by a single strand), terminal 1 does not detect battery voltage. Control unit does not detect the switch is ON even if the switch does not turn ON. Therefore, the control unit does not supply power to light up the CASE 2 INPUT-OUTPUT VOLTAGE CHART • The voltage value is based on the body ground. • *: If high resistance exists in the switch side circuit (caused by a single strand), terminal 2 does not detect approx. 0 V. Control unit does not detect the switch is ON even if the switch does not turn ON. Therefore, the control unit does not control ground to light up the Terminal No. Description Condition Value (Approx.) In case of high resistance such as single + − Signal name Input/ Output 1 Body Switch Input Switch ON Battery voltage Lower than battery voltage Approx. 8 (Ex- Switch OFF 0 V Approx. 0 2 Body Lamp Output Switch ON Battery voltage Approx. 0 (Inoperative lamp) Switch OFF 0 V Approx. 0 Terminal No. Description Condition Value (Approx.) In case of high resistance such as single + − Signal name Input/ Output 1 Body Lamp Output Switch ON 0 V Battery voltage (Inoperative lamp) Switch OFF Battery voltage Battery voltage 2 Body Switch Input Switch ON 0 V Higher than 0 Approx. 4 (Example) Switch OFF 5 V Approx. 5 MGI035A |