DLK-358 < DTC/CIRCUIT DIAGNOSIS > AUTOMATIC SLIDING DOOR MOTOR AUTOMATIC SLIDING DOOR MOTOR SLIDING DOOR LH SLIDING DOOR LH : Diagnosis Procedure INFOID:0000000009649311 1. CHECK AUTOMATIC SLIDING DOOR MOTOR INPUT SIGNAL 1. Turn ignition switch OFF. 2. Disconnect sliding door control unit LH connector. 3. Check voltage between sliding door control unit LH harness connector and ground. Is the inspection result normal? YES >> GO TO 2. NO >> Replace sliding door control unit LH. Refer to DLK-500, "LH : Removal and Installation" 2. CHECK AUTOMATIC SLIDING DOOR MOTOR CIRCUIT 1. Disconnect automatic sliding door unit LH connector. 2. Check continuity between sliding door control unit LH harness connector and automatic sliding door unit 3. Check continuity between sliding door control unit LH harness connector and ground. Is the inspection result normal? YES >> Replace automatic sliding door unit LH. NO >> Repair or replace harness. SLIDING DOOR RH SLIDING DOOR RH : Diagnosis Procedure INFOID:0000000009649312 1. CHECK AUTOMATIC SLIDING DOOR MOTOR INPUT SIGNAL 1. Turn ignition switch OFF. 2. Disconnect sliding door control unit RH connector. 3. Check voltage between sliding door control unit RH harness connector and ground. (+) (–) Condition Voltage Sliding door control unit LH Connector Terminal B47 43 Ground Sliding door LH Open operate 9 – 16 V 46 Close operate Sliding door control unit LH Automatic sliding door unit LH Continuity Connector Terminal Connector Terminal B47 43 B33 3 Existed 46 4 Sliding door control unit LH Ground Continuity Connector Terminal B47 43 Not existed 46 (+) (–) Condition Voltage Sliding door control unit RH Connector Terminal B249 43 Ground Sliding door RH Open operate 9 – 16 V 46 Close operate |