Content .. 1008 1009 1010 1011 ..
PWO-28 < DTC/CIRCUIT DIAGNOSIS > [AC 120 V OUTLET] AC 120 V POWER OUTPUT CIRCUIT CAUTION: • To measure AC 120 V output signal, always use the circuit tester AC range. Is the inspection result normal? YES >> INSPECTION END NO >> Replace AC 120 V outlet. Terminals Condition Standard value Voltage (Approx.) (+) (-) AC 120 V outlet AC 120 V outlet main switch Terminal 1 2 OFF Approx. 0 V 0 V ON AC 108 – 132 V AC 120 V |