B210C STARTER CONTROL RELAY SEC-115 < DTC/CIRCUIT DIAGNOSIS > [WITH INTELLIGENT KEY SYSTEM] C D E F G H I J L M A B SEC N O P 3. CHECK STARTER CONTROL RELAY CONTROL CIRCUIT CONTINUITY 1. Disconnect IPDM E/R connector E44 and clutch interlock switch connector E34. 2. Check continuity between IPDM E/R connector E44 and clutch interlock switch connector E34. 3. Disconnect BCM connector M98. 4. Check continuity between IPDM E/R connector E44 and ground. Is the inspection result normal? YES >> Replace BCM. Refer to BCS-70, "Removal and Installation" NO >> Repair or replace harness or connectors. 4. CHECK STARTER CONTROL RELAY CONTROL CIRCUIT CONTINUITY 1. Disconnect IPDM E/R connector F42 and transmission range switch connector F52. 2. Check continuity between IPDM E/R connector F42 and transmission range switch connector F52. 3. Disconnect BCM connector M98. 4. Check continuity between IPDM E/R connector F42 and ground. Is the inspection result normal? YES >> Replace BCM. Refer to BCS-70, "Removal and Installation" NO >> Repair or replace harness or connectors. IPDM E/R Clutch interlock switch Continuity Connector Terminal Connector Terminal E44 13 E34 2 Yes IPDM E/R Ground Continuity Connector Terminal E44 13 — No IPDM E/R Transmission range switch Continuity Connector Terminal Connector Terminal F42 40 F52 10 Yes IPDM E/R Ground Continuity Connector Terminal F42 40 — No |