SEC-64 < DTC/CIRCUIT DIAGNOSIS > [WITH INTELLIGENT KEY SYSTEM] B2555 STOP LAMP 1. Connect stop lamp switch connector. 2. Check voltage between BCM harness connector and ground. Is the inspecting result normal? YES >> GO TO 4. NO >> GO TO 5. 4. REPLACE BCM 1. Replace BCM. Refer to BCS-69, "Removal and Installation" . 2. Perform initialization of BCM and registration of all Intelligent Keys using CONSULT. >> Inspection End. 5. CHECK STOP LAMP SWITCH CIRCUIT 1. Disconnect stop lamp switch connector. 2. Check continuity between stop lamp switch harness connector and BCM harness connector. 3. Check continuity between stop lamp switch harness connector and ground. Is the inspection result normal? YES >> GO TO 6. NO >> Repair or replace harness. 6. CHECK STOP LAMP SWITCH SEC-64, "Component Inspection" . Is the inspection result normal? YES >> GO TO 7. NO >> Replace stop lamp switch. Refer to . 7. CHECK INTERMITTENT INCIDENT GI-45, "Intermittent Incident" >> Inspection End. Component Inspection INFOID:0000000009268404 1. CHECK STOP LAMP SWITCH 1. Turn ignition switch OFF. 2. Disconnect stop lamp switch connector. 3. Check continuity between stop lamp switch terminals. (+) (–) Condition Voltage (V) (Approx.) BCM Connector Terminal M97 9 Ground Brake pedal Depressed Battery voltage Not depressed 0 Stop lamp switch BCM Continuity Connector Terminal Connector Terminal E13 2 M97 9 Yes Stop lamp switch Ground Continuity Connector Terminal E13 2 No |