HO2S1 HEATER EC-493 < DTC/CIRCUIT DIAGNOSIS > [HR12DE (TYPE 2)] C D E F G H I J K L M A EC N P O • Harness connectors E6, F1 >> Repair or replace harness or connectors. 4. CHECK HO2S1 HEATER OUTPUT SIGNAL CIRCUIT 1. Turn ignition switch OFF. 2. Disconnect ECM harness connector. 3. Check the continuity between HO2S1 harness connector and ECM harness connector. 4. Also check harness for short to ground and short to power. Is the inspection result normal? YES >> GO TO 5. NO >> Repair open circuit or short to ground or short to power in harness or connectors. 5. CHECK HO2S1 HEATER EC-493, "Component Inspection" Is the inspection result normal? YES >> GO TO 7. NO >> GO TO 6. 6. REPLACE HEATED OXYGEN SENSOR 1 Replace heated oxygen sensor 1. CAUTION: • Discard any heated oxygen sensor which has been dropped from a height of more than 0.5 m (19.7 in) onto a hard surface such as a concrete floor; use a new one. • Before installing new heated oxygen sensor, clean exhaust system threads using Oxygen Sensor Thread Cleaner (commercial service tool) and approved Anti-seize Lubricant (commercial service >> INSPECTION END 7. CHECK INTERMITTENT INCIDENT Perform XX-XX, "*****" . >> INSPECTION END Component Inspection INFOID:0000000005886638 1. CHECK HEATED OXYGEN SENSOR 1 1. Turn ignition switch OFF. 2. Disconnect heated oxygen sensor 1 harness connector. 3. Check resistance between HO2S1 terminals as follows. Is the inspection result normal? HO2S1 ECM Continuity Connector Terminal Connector Terminal F46 3 F7 3 Existed Terminals Resistance [at 25 ° C (77 ° F)] 2 and 3 3.4 - 4.4 Ω