REFRIGERANT PRESSURE SENSOR EC-297 < DTC/CIRCUIT DIAGNOSIS > [HR12DE (TYPE 1)] C D E F G H I J K L M A EC N P O REFRIGERANT PRESSURE SENSOR Component Function Check INFOID:0000000005989409 1. CHECK REFRIGERANT PRESSURE SENSOR OVERALL FUNCTION 1. Start engine and warm it up to normal operating temperature. 2. Turn A/C switch and blower fan switch ON. 3. Check the voltage between ECM harness connector and ground. Is the inspection result normal? YES >> INSPECTION END NO >> Go to Diagnosis Procedure INFOID:0000000005989410 1. CHECK GROUND CONNECTION 1. Turn A/C switch and blower fan switch OFF. 2. Stop engine. 3. Turn ignition switch OFF. 4. Check ground connection E38. Refer to Ground Inspection in . Is the inspection result normal? YES >> GO TO 2. NO >> Repair or replace ground connection. 2. CHECK REFRIGERANT PRESSURE SENSOR POWER SUPPLY CIRCUIT 1. Disconnect refrigerant pressure sensor harness connector. 2. Turn ignition switch ON. 3. Check the voltage between refrigerant pressure sensor harness connector and ground. Is the inspection result normal? YES >> GO TO 4. NO >> GO TO 3. 3. DETECT MALFUNCTIONING PART Check the following. >> Repair open circuit or short to ground or short to power in harness or connectors. 4. CHECK REFRIGERANT PRESSURE SENSOR GROUND CIRCUIT FOR OPEN AND SHORT 1. Turn ignition switch OFF. 2. Disconnect ECM harness connector. 3. Check the continuity between refrigerant pressure sensor harness connector and ECM harness connec- ECM Voltage Connector + − Terminal Terminal F8 41 (Refrigerant pressure sensor signal) 48 1.0 - 4.0V Refrigerant pressure sensor Ground Voltage Connector Terminal E49 3 Ground Approx. 5 V |