|
|
содержание .. 865 866 867 868 ..
PRECAUTIONS HAC-123 < PRECAUTION > [WITHOUT 7 INCH DISPLAY] C D E F G H J K L M A B HAC N O P • Perform leakage test and make sure that there is no leakage from connections after connecting line. Disconnect the line and replace the O-ring when the refrigerant leaking point is found. Then tighten Service Equipment INFOID:0000000005514669 RECOVERY/RECYCLING EQUIPMENT Be certain to follow the manufacturer instructions for machine operation and machine maintenance. Never ELECTRICAL LEAK DETECTOR Be certain to follow the manufacturer instructions for tester operation and tester maintenance. VACUUM PUMP The lubricant contained inside the vacuum pump is not compatible pump. Close this valve to isolate the service hose from the pump. • Use a hose equipped with a manual shut-off valve near the pump end for pumps without an isolator. Close the valve to isolate the • Disconnect the hose from the pump if the hose has an automatic shut-off valve. As long as the hose is connected, the valve is open Some one-way valves open when vacuum is applied and close MANIFOLD GAUGE SET RHA861F RHA270DA |