B2581, B2582 INTAKE SENSOR HAC-51 < DTC/CIRCUIT DIAGNOSIS > [WITHOUT 7 INCH DISPLAY] C D E F G H J K L M A B HAC N O P B2581, B2582 INTAKE SENSOR Description INFOID:0000000005514610 Intake Sensor into a resistance value which is then input to the A/C auto amp. Intake Sensor Circuit DTC Logic INFOID:0000000005514611 DTC DETECTION LOGIC NOTE: . DTC CONFIRMATION PROCEDURE 1. CHECK WITH SELF-DIAGNOSIS FUNCTION OF CONSULT-III 1. Using CONSULT-III, perform “SELF-DIAGNOSIS RESULTS” of HVAC. 2. Check if any DTC No. is displayed in the self-diagnosis results. NOTE: . Is DTC No.“B2581” or “B2582” displayed? YES >> Perform trouble diagnosis for the intake sensor. Refer to . NO >> INSPECTION END Diagnosis Procedure INFOID:0000000005514612 1. CHECK VOLTAGE BETWEEN INTAKE SENSOR AND GROUND JPIIA1351ZZ JPIIA0614GB DTC Items (CONSULT-III screen terms) Diagnostic item is detected when... Possible cause B2581 EVAP TEMP SEN SHORT Detected temperature at intake sensor − 33 ° C ( − 27 ° F) or less • Intake sensor (Intake sensor circuit is open, or there is a B2582 EVAP TEMP SEN OPEN Detected temperature at intake sensor ° C (156 ° F) or more |