содержание .. 1342 1343 1344 1345 ..
SRC-146 < DTC/CIRCUIT DIAGNOSIS > [FOR USA AND CANADA] B1202, B1203, B1204, B1205, B1206, B1207 DIAGNOSIS SENSOR UNIT >> GO TO 2. 2. CHECK AIR BAG WARNING LAMP Check the air bag warning lamp status. Is malfunctioning part detected? YES >> Refer to warning lamp flash code chart. NO >> INSPECTION END. Diagnosis Procedure INFOID:0000000005513672 With CONSULT-III WARNING: • Before servicing, turn ignition switch OFF, disconnect battery negative terminal and wait at least 3 minutes. (To discharge backup capacitor.) • Do not use unspecified tester or other measuring device. DIAGNOSTIC PROCEDURE 1. CHECK HARNESS CONNECTOR Check the connection of harness connector. Is the inspection result normal? YES >> GO TO 2. NO >> Repair or replace harness connectors. 2. CHECK WIRING HARNESS Check the wiring harness externals. Is the inspection result normal? YES >> GO TO 3. NO >> Repair or replace wiring harness. 3. CHECK AIR BAG DIAGNOSIS SENSOR UNIT 1. Replace air bag diagnosis sensor unit. 2. Check the screen of CONSULT-III. Is the inspection result normal? YES >> INSPECTION END. NO >> Check the intermittent incident. Refer to GI-39, "Intermittent Incident" . |