Nissan X-Trail 32. Manual - part 2166

 

 

TM-622

< DTC/CIRCUIT DIAGNOSIS >

[CVT: RE0F10G]

P0966 PRESSURE CONTROL SOLENOID B

P0966 PRESSURE CONTROL SOLENOID B

DTC Description

INFOID:0000000010622844

DTC DETECTION LOGIC

POSSIBLE CAUSE

• Harness or connector (Primary pressure solenoid valve circuit shorted to ground)
• Primary pressure solenoid valve

FAIL-SAFE

• Selector shock is large
• Start  is  slow
• Acceleration is slow
• Lock-up is not performed
• Stop/start system prohibited
• Restart the engine during the stop/start system operation
• Turn OFF the electric oil pump relay

DTC CONFIRMATION PROCEDURE

1.

PREPARATION BEFORE WORK

If another "DTC CONFIRMATION PROCEDURE" occurs just before, turn ignition switch OFF and wait for at
least 10 seconds, then perform the next test.

>> GO TO 2.

2.

CHECK DTC DETECTION

1.

Start the engine and wait for 5 seconds or more.

2.

Check the first trip DTC.

Is “P0966” detected?

YES

>> Go to 

TM-622, "Diagnosis Procedure"

.

NO-1

>> To check malfunction symptom before repair: Refer to 

GI-44, "Intermittent Incident"

.

NO-2

>> Confirmation after repair: INSPECTION END

Diagnosis Procedure

INFOID:0000000010622845

1.

CHECK CIRCUIT BETWEEN TCM AND CVT UNIT

1.

Turn ignition switch OFF.

2.

Disconnect TCM connector and CVT unit connector.

3.

Check continuity between TCM harness connector terminal and ground. 

Is the inspection result normal?

YES 

>> GO TO 2.

NO

>> Repair or replace damaged parts.

2.

CHECK PRIMARY PRESSURE SOLENOID VALVE CIRCUIT

Check continuity between CVT unit harness connector terminal and ground. 

DTC

CONSULT screen terms

(Trouble diagnosis content)

DTC detection condition

P0966

PC SOLENOID B
(Pressure Control Solenoid B Control Circuit 
Low)

When all of the following conditions are satisfied and this state is main-
tained for 0.48 seconds:
• TCM power supply voltage: More than 11 V
• TCM judges that solenoid valve circuit is shorted to ground.

TCM

Continuity

Connector

Terminal

F119

40

Ground

Not existed

P0966 PRESSURE CONTROL SOLENOID B

TM-623

< DTC/CIRCUIT DIAGNOSIS >

[CVT: RE0F10G]

C

E

F

G

H

I

J

K

L

M

A

B

TM

N

O

P

Is the inspection result normal?

YES >> INSPECTION 

END

NO

>> There is malfunction of primary pressure solenoid valve. Replace transaxle assembly. Refer to

TM-704, "Removal and Installation"

.

CVT unit

Condition

Resistance

Connector

Terminal

F250

2

Ground

CVT fluid temperature: 20

°

C (68

°

F)

5.5 – 7.0 

CVT fluid temperature: 50

°

C (122

°

F)

6.0 – 8.0 

CVT fluid temperature: 80

°

C (176

°

F)

6.5 – 8.5 

TM-624

< DTC/CIRCUIT DIAGNOSIS >

[CVT: RE0F10G]

P0967 PRESSURE CONTROL SOLENOID B

P0967 PRESSURE CONTROL SOLENOID B

DTC Description

INFOID:0000000010622846

DTC DETECTION LOGIC

POSSIBLE CAUSE

• Harness or connector (Primary pressure solenoid valve circuit open or shorted to power supply)
• Primary pressure solenoid valve

FAIL-SAFE

• Selector shock is large
• Start  is  slow
• Acceleration is slow
• Lock-up is not performed
• Stop/start system prohibited
• Restart the engine during the stop/start system operation
• Turn OFF the electric oil pump relay

DTC CONFIRMATION PROCEDURE

1.

PREPARATION BEFORE WORK

If another "DTC CONFIRMATION PROCEDURE" occurs just before, turn ignition switch OFF and wait for at
least 10 seconds, then perform the next test.

>> GO TO 2.

2.

CHECK DTC DETECTION

1.

Start the engine and wait for 5 seconds or more.

2.

Check the first trip DTC.

Is “P0967” detected?

YES

>> Go to 

TM-624, "Diagnosis Procedure"

.

NO-1

>> To check malfunction symptom before repair: Refer to 

GI-44, "Intermittent Incident"

.

NO-2

>> Confirmation after repair: INSPECTION END

Diagnosis Procedure

INFOID:0000000010622847

1.

CHECK CIRCUIT BETWEEN TCM AND CVT UNIT

1.

Turn ignition switch OFF.

2.

Disconnect TCM connector and CVT unit connector.

3.

Check continuity between TCM harness connector terminal and CVT unit harness connector terminal. 

Is the inspection result normal?

YES 

>> GO TO 2.

NO

>> Repair or replace damaged parts.

2.

CHECK PRIMARY PRESSURE SOLENOID VALVE CIRCUIT

DTC

CONSULT screen terms

(Trouble diagnosis content)

DTC detection condition

P0967

PC SOLENOID B
(Pressure Control Solenoid B Control Circuit 
High)

When all of the following conditions are satisfied and this state is main-
tained for 0.2 seconds:
• TCM power supply voltage: More than 11 V
• P0966 is not detected
• TCM judges that solenoid valve circuit is open.

TCM

CVT unit

Continuity

Connector

Terminal

Connector

Terminal

F119

40

F127

2

Existed

P0967 PRESSURE CONTROL SOLENOID B

TM-625

< DTC/CIRCUIT DIAGNOSIS >

[CVT: RE0F10G]

C

E

F

G

H

I

J

K

L

M

A

B

TM

N

O

P

Check continuity between CVT unit harness connector terminal and ground. 

Is the inspection result normal?

YES >> INSPECTION 

END

NO

>> There is malfunction of primary pressure solenoid valve. Replace transaxle assembly. Refer to

TM-704, "Removal and Installation"

.

CVT unit

Condition

Resistance

Connector

Terminal

F250

2

Ground

CVT fluid temperature: 20

°

C (68

°

F)

5.5 – 7.0 

CVT fluid temperature: 50

°

C (122

°

F)

6.0 – 8.0 

CVT fluid temperature: 80

°

C (176

°

F)

6.5 – 8.5 

 

 

 

 

 

 

 