Content .. 1211 1212 1213 1214 ..
Item No. Check items Inspection status The display contents under normal 68 Front blower fan - Displays blower motor condition. 69 Front blower fan (Target) - Displays blower motor target value. 73 Refrigerant pressure - Displays 74 Condenser fan - Displays fan running condition. 76 Temp. set dial position - Displays the set on the control panel. 77 A/C Panel type - Dial/Auto/RHD 78 Fan set dial position - Displays the air output value on the control panel. 79 Air outlet c/o set dial - Displays output value to the air 80 Fan set dial operation - ON when the air 81 A/C SW operation flag - ON when the air 82 Temp. set dial operation - ON when the air 83 Defogger flag - ON when the air 84 In/out air c/o SW - ON when the inside air/outside changeover switch is operated AUTOMATIC AIR CONDITIONING 55B-15 AUTO A/C DIAGNOSIS |