Infiniti G37 Coupe. Manual - part 1215

 

  Index      Infiniti     Infiniti G37 Coupe - service repair manual 2008 year

 

Search            

 

 

 

 

 

 

 

 

 

Content   ..  1213  1214  1215  1216   ..

 

 

Infiniti G37 Coupe. Manual - part 1215

 

 

SRC-110

< COMPONENT DIAGNOSIS >

B1138, B1139, B1140, B1141, B1142, B1143 DIAGNOSIS SENSOR UNIT

>> GO TO 2.

2.

CHECK AIR BAG WARNING LAMP

Check the warning lamp status.

Is malfunctioning part detected?

YES

>> Refer to 

SRC-133, "DTC Index"

.

NO

>> INSPECTION END.

Diagnosis Procedure (Component diagnosis)

INFOID:0000000001694616

With CONSULT-lll

WARNING:

• Before servicing, turn ignition switch OFF, disconnect both battery terminals and wait at least 3 min-

utes. (To discharge backup capacitor.)

• Do not use unspecified tester or other measuring device. 

DIAGNOSTIC PROCEDURE

1.

CHECK HARNESS CONNECTOR

Check the connection of harness connector.

Is the inspection result normal?

YES

>> GO TO 2.

NO

>> Repair or replace harness connectors.

2.

CHECK WIRING HARNESS

Check the wiring harness externals.

Is the inspection result normal?

YES

>> GO TO 3.

NO

>> Replace wiring harness.

3.

CHECK DIAGNOSIS SENSOR UNIT

1.

Replace diagnosis sensor unit (ACU).

2.

Check the screen of CONSULT-III.

Is the inspection result normal?

YES

>> INSPECTION END.

NO

>> Check the intermittent incident. Refer to 

GI-38, "Intermittent Incident"

.

B1145 CURTAIN MODULE RH

SRC-111

< COMPONENT DIAGNOSIS >

C

D

E

F

G

I

J

K

L

M

A

B

SRC

N

O

P

B1145 CURTAIN MODULE RH

Description

INFOID:0000000001694617

DTC B1145 [OPEN] CURTAIN MODULE RH

For RH side curtain air bag module, crash is judged by main “G” sensor output signal (left side: LH satellite
sensor, right side: RH satellite sensor) and sub “G” sensor (right and left GP in center unit).

OPERATION

In case of collision whose acceleration exceeds the specified level, the ignition materials are ignited by electric
ignition system. The system burns and introduces the chemical reaction of gas generating materials to gener-
ate hot gases that flow into the air bag through a filter and expand the bag.

STRUCTURE

RH side curtain air bag module mainly consists of air bag and inflator which inflates air bag.

INSTALLATION

RH side curtain air bag module is installed on the roof side with fixed bolts.

DTC Logic

INFOID:0000000001694618

DTC DETECTION LOGIC

With CONSULT-lll

DTC No. Index (“SELF-DIAG [CURRENT]”), (“SELF-DIAG [PAST]” or “TROUBLE DIAG RECORD”)

DTC CONFIRMATION PROCEDURE (With CONSULT-lll)

1.

INSPECTION START

Turn ignition switch ON.

>> GO TO 2.

2.

CHECK SELF-DIAG RESULT

Check the screen of CONSULT-lll.

Is malfunctioning part detected?

YES

>> Refer to 

SRC-112, "Diagnosis Procedure (Component diagnosis)"

.

NO

>> INSPECTION END.

DTC CONFIRMATION PROCEDURE (Without CONSULT-lll)

NOTE:
• SRS will not enter diagnosis mode if no malfunction is detected in user mode.

1.

INSPECTION START

Turn ignition switch ON.

>> GO TO 2.

DTC No.

Trouble diagnosis name

DTC detecting condition

Possible cause

B1145

CURTAIN MODULE RH 
[OPEN]

RH side curtain air bag module circuit is 
open.

• Disconnection of wiring harness and 

open.

• Internal breakdown in RH side cur-

tain air bag module.

• Replace diagnosis sensor unit 

(ACU).

SRC-112

< COMPONENT DIAGNOSIS >

B1145 CURTAIN MODULE RH

2.

CHECK AIR BAG WARNING LAMP

Check the warning lamp status.
Is malfunctioning part detected?

YES

>> Refer to 

SRC-133, "DTC Index"

.

NO

>> INSPECTION END.

Diagnosis Procedure (Component diagnosis)

INFOID:0000000001694619

With CONSULT-lll

WARNING:

• Before servicing, turn ignition switch OFF, disconnect both battery terminals and wait at least 3 min-

utes. (To discharge backup capacitor.)

• Do not use unspecified tester or other measuring device. 

DIAGNOSTIC PROCEDURE

1.

CHECK HARNESS CONNECTOR

Check the connection of harness connector.

Is the inspection result normal?

YES

>> GO TO 2.

NO

>> Repair or replace harness connector.

2.

CHECK WIRING HARNESS

Check the wiring harness externals.

Is the inspection result normal?

YES

>> GO TO 3. 

NO

>> Repair or replace wiring harness.

3.

CHECK SIDE CURTAIN AIR BAG MODULE

1.

Replace RH side curtain air bag module.

2.

Check the screen of CONSULT-lll.

Is the inspection result normal?

YES

>> INSPECTION END.

NO

>> Check the intermittent incident. Refer to 

GI-38, "Intermittent Incident"

.

B1146 CURTAIN MODULE RH

SRC-113

< COMPONENT DIAGNOSIS >

C

D

E

F

G

I

J

K

L

M

A

B

SRC

N

O

P

B1146 CURTAIN MODULE RH

Description

INFOID:0000000001694620

DTC B1146 [VB-SHORT] CURTAIN MODULE RH

For RH side curtain air bag module, crash is judged by main “G” sensor output signal (left side: LH satellite
sensor, right side: RH satellite sensor) and sub “G” sensor (right and left GP in center unit).

OPERATION

In case of collision whose acceleration exceeds the specified level, the ignition materials are ignited by electric
ignition system. The system burns and introduces the chemical reaction of gas generating materials to gener-
ate hot gases that flow into the air bag through a filter and expand the bag.

STRUCTURE

RH side curtain air bag module mainly consists of air bag and inflator which inflates air bag.

INSTALLATION

RH side curtain air bag module is installed on the roof side with fixed bolts.

DTC Logic

INFOID:0000000001694621

DTC DETECTION LOGIC

With CONSULT-lll

DTC No. Index (“SELF-DIAG [CURRENT]”), (“SELF-DIAG [PAST]” or “TROUBLE DIAG RECORD”)

DTC CONFIRMATION PROCEDURE (With CONSULT-lll)

1.

INSPECTION START

Turn ignition switch ON.

>> GO TO 2.

2.

CHECK SELF-DIAG RESULT

Check the screen of CONSULT-lll.

Is malfunctioning part detected?

YES

>> Refer to 

SRC-114, "Diagnosis Procedure (Component diagnosis)"

.

NO

>> INSPECTION END.

DTC CONFIRMATION PROCEDURE (Without CONSULT-lll)

NOTE:
• SRS will not enter diagnosis mode if no malfunction is detected in user mode.

1.

INSPECTION START

Turn ignition switch ON.

>> GO TO 2.

DTC No.

Trouble diagnosis name

DTC detecting condition

Possible cause

B1146

CURTAIN MODULE RH 
[VB-SHORT]

RH side curtain air bag module circuit is 
shorted to some power supply circuit.

• Disconnection of wiring harness and 

short.

• Internal breakdown in RH side cur-

tain air bag module.

• Internal breakdown in diagnosis sen-

sor unit (ACU).

 

 

 

 

 

 

 

Content   ..  1213  1214  1215  1216   ..