Content .. 1831 1832 1833 1834 ..
TCM TM-139 < ECU DIAGNOSIS INFORMATION > [7AT: RE7R01A (VQ35HR)] C E F G H I J K L M A B TM N O P 4 (V) — K-line Input/ Output — — 5 (B) Ground Ground Output Always 0 V 6 (Y) Ground Power supply Input Ignition switch ON Battery voltage Ignition switch OFF 0 V 7 (R) Ground Back-up lamp relay Input Ignition switch ON Selector lever in “R” position. 0 V Selector lever in other positions. Battery voltage 8 (P) — CAN-L Input/ Output — — 9 (GR) Ground Starter relay Output Ignition switch ON Selector lever in “N” and “P” po- Battery voltage Selector lever in other positions. 0 V 10 (B) Ground Ground Output Always 0 V Terminal (Wire color) Description Condition Value (Approx.) + − Signal name Input/ Output |