Hyundai Santa Fe (2006 year). Manual - part 154

 

  Index      Hyundai     Hyundai Santa Fe - service repair manual 2006 year

 

Search            

 

 

 

 

 

 

 

 

 

Content   ..  152  153  154  155   ..

 

 

Hyundai Santa Fe (2006 year). Manual - part 154

 

 

ETACS (ELECTRONIC TIME AND ALARM CONTROL SYSTEM)

BE -77

11. KEY OPERATED WARNING

1)

In state of KEY IN SW is IN, if the DRIVER DOOR
is opened, then the CHIME BUZZER output shall
be continued with the cycle of 0.7 seconds.

2)

If KEY IN SW is OUT or the driver’s door is closed
during the Chime Buzzer output, then the output
shall be OFF.

ON

OFF

KEY IN
SW

DRIVER
DOOR SW

CHIME
BUZZER

IN

OUT

OPEN
CLOSE

T1

SCMBE6163L

T1 : 0.7 ± sec.

12. OVER SPEED WARNING

In the IGN 2 ON state, if the over speed SW of the
cluster is On, the chime buzzer output shall be ON.
If the over speed SW is OFF, the chime buzzer output
shall be OFF.

OVER
SPEED
SW 

ON

OFF

CHIME
BUZZER

ON

OFF

IGN 2

ON

OFF

T1 T1

SCMBE6904L

T1 : 0.5 ± 0.1 sec.

13. PARKING START WARNING

In the state that the IGN1 is ON or the Parking Brake
is pulled, if the speed of vehicle is maintained over 10
km/h for 2~3 seconds or more, then the Chime Buzzer
output shall be continued with 1 second cycle of the
ON/OFF (0.3/0.7 seconds). But, after the speed of
vehicle is maintained over 10 km/h for 2~3 seconds
or more, if the Parking Brake is pulled, output imme-
diately.

ON

OFF

ON

OFF

ON

OFF

T2

T1

T3

IGN1

P/BRAKE
SW

VEHICLE
SPEED

CHIME
BUZZER

OVER
 10KPH
UNDER
10KPH

SCMBE6164L

T1 : 2.5±0.5 sec, T2 : 0.3±0.1 sec,
T3 : 0.7±0.1 sec.

BE -78

BODY ELECTRICAL SYSTEM

14. IGN KEY HOLE ILLUMINATION

1)

If the driver’s door (or assist’ s door) is opened
in the state that the IGN1 SW is OFF, then the
IGN Key Hole Illumination shall be ON.

2)

In the (1) state, if the driver’s door (or assist’s
door) is closed, then the IGN Key Hole Illumina-
tion shall be OFF after it is in the ON state for 30
seconds.

3)

During the (1) and (2) operating, if the IGN1 SW
is On, the IGN Key Hole Illumination shall be OFF
immediately.

4)

But, if it is in the ARM Mode, then the IGN Key
Hole Illumination shall be OFF immediately.

ON
OFF

ON
OFF

OPEN

CLOSE

IGN1

DRIVER
or ASSIST
DOOR SW

KEY ILL.
LAMP

T1

T1

T1

SCMBE6165L

T1 : 30 ± 1 sec.

15. DEFOGGER TIMER

1)

If the Defogger SW is ON after the ALT "L" is ON
in the state that the IGN1 SW is ON, then the De-
fogger output shall be ON for 20 minutes. (Oper-
ating in the state of the ENGINE RUNNING)

2)

If the DEFOGGER SW is ON again while the DE-
FOGGER output is ON, then the DEFOGGER
output shall be OFF.

3)

If the ALT "L" is OFF or IGN1 is OFF while the
DEFOGGER output is ON, then the DEFOGGER
output shall be OFF.

4)

If the ALT "L" > 10 volts, then it shall be in the
Engine Running State (ALT "L" shall be ON); if
the ALT "L" < 5 volts, then it shall be in the En-
gine Stop State (ALT "L" shall be OFF). Also, if
the ALT "L" is more than 5 and less than 10 volts,
then the former state shall be maintained.

5)

If the defogger SW is pressed and the ALT "L"
is ON, there shall be no the DEFOGGER RLY
output.

ON
OFF

ON
OFF

ON
OFF

ON
OFF

IGN1

ATL 'L'

DEICER
SW

DEICER
RELAY

T1

T1

T1

T2

T2

T2

SCMBE6166L

T1 : 60 ± 20 msec, T2 : 20 ± 1 min.

ETACS (ELECTRONIC TIME AND ALARM CONTROL SYSTEM)

BE -79

16. DECAYED ROOM LAMP & KEYLESS UNLOCK

TIMER

CONDITION 1

State

Description

Initial Condition

Room lamp OFF & IGN1 OFF & 4DOOR AND T/GATE CLOSE

Transition Condition

In the state that all doors are closed, the 4DOOR or T/GATE is opened over 0.1 seconds.

Operating

-

Entry into the ROOM LAMP ON state for 20 min

-

ROOM LAMP ON for 20 ± 1 min

CONDITION 2

State

Description

Initial Condition

Room lamp OFF & IGN1 OFF & 4DOOR AND T/GATE CLOSE

Transition Condition

In case of UNLOCK by the TX

Operating

-

Entry into the ROOM LAMP ON state for 30s

-

ROOM LAMP ON for 30 ± 3seconds

CONDITION 3

State

Description

Initial Condition

Room lamp OFF & IGN1 OFF & 4DOOR AND T/GATE CLOSE

Transition Condition

IGN1 ON and 4 DOOR or T/GATE OPEN over 0.1 seconds

Operating

-

Entry into the ROOM LAMP ON state

-

ROOM LAMP ON

ON
OFF

ON
OFF

ON
OFF

OPEN

CLOSE

IGN1

T1

T2

T3

DOOR

UNLOCK

ROOM
LAMP

SCMBE6167L

T1 : 20 ± 1 min, T2 : 30 ± 3 sec,
T3 : 100 ms.

BE -80

BODY ELECTRICAL SYSTEM

CONDITION 4

State

Description

Initial Condition

ROOM LAMP ON for 30s & IGN1 OFF

Transition Condition

In the state that all doors are closed, the 4DOOR or T/GATE is opened over 0.1 seconds.

Operating

-

Entry into the ROOM LAMP ON state for 20 min

-

ROOM LAMP ON for 20 ± 1min.

CONDITION 5

State

Description

Initial Condition

ROOM LAMP ON for 30s & IGN1 OFF

Transition Condition

In case of UNLOCK by the TX.

Operating

-

Maintain in the ROOM LAMP ON state for 30s

-

Extend the ROOM LAMP ON state for 30 seconds.

CONDITION 6

State

Description

Initial Condition

ROOM LAMP ON for 30s & IGN1 OFF

Transition Condition

IGN1 ON, or after 30 seconds, or when entered into the ARM state,
or when all doors are locked.

Operating

-

Entry into the ROOM LAMP DECAYING state

-

After the ROOM LAMP is decayed for 2 ± 0.2 seconds, it shall be OFF.

DOOR

OPEN

CLOSE

IGN 1

ON

OFF

UNLOCK

ON

OFF

ROOM
LAMP

ON

OFF

T2

T1

All DOOR

LOCK
SW

LOCK

UNLOCK

T2

T2

T2

T3

T2

SCMBE6905L

T1 : 20 ± 1 min, T2 : 30 ± 3 sec,
T3 : 100 ms.

 

 

 

 

 

 

 

Content   ..  152  153  154  155   ..