Great Wall Hover. Manual - part 94

 

  Index      Great Wall     Great Wall Hover - service repair manual

 

Search            copyright infringement  

 

 

 

 

 

 

 

 

 

Content   ..  92  93  94  95   ..

 

 

Great Wall Hover. Manual - part 94

 

 

Safety airbag-13

Internal failure

Failure code   

$9071  

SRS safety airbag system unit internal failure 

Test condition   

Warning 

The test condition of this failure is the failure code that may not emerge before the test, 

DTC conducts the test, and the preparatory work must be done before the test because the 

damage to working personnel or system may be caused by the incorrect operation during the 

test. 

SRS safety airbag system electronic-control unit internal circuit failure. 

Possible causes   

SRS safety airbag system unit internal failure 

Operation  

With regard to replacing SRS safety airbag system unit, take references in the removal/installation of safety airbag system 

Safety airbag-14

Power-supply

 

Failure code 

$9032 

Low power-supply voltage for SRS safety airbag system electronic-control unit   

Test condition 

Warning 

The test condition of this failure is the failure code that may not emerge before the test, DTC conducts the test, 

and the preparatory work must be done before the test because the damage to working personnel or system 

may be caused by the incorrect operation during the test. 

The voltage for SRS safety airbag system unit connector clip is stitch 5 and 6 is under 9V 

Possible 

causes 

Accumulator low voltage 

Failure with the wiring harness between accumulator and SRS safety airbag system electronic-control unit 

Procedure Test 

 

Operation 

Yes   Next step 

Check accumulator   

Test accumulator voltage   

Is the voltage above 9V 

No   Accumulator low voltage, test the 

recharging/discharging system 

Yes   Next step 

Check the wiring harness between accumulator and fuse 

panel 

Remove fuse panel without releasing the connector clips 

Place the ignition switch in ON position 

Test the potential of two fuse corresponding contactors, the 

potential above 9V? 

No   Check the wiring harness 

Yes   Next step 

Check the wiring harness between fuse panel and SRS 

safety airbag system unit connector clip 

Warning:    

If not correctly handled, the safety airbag module as well 

as pretension safety belt may possibly be trigged, released 

and tensioned, thus make serene damage to people. 

Therefore, please carefully read the repairing warning 

before trouble handling. Please take references in safety 

airbag system repairing warning   

Place the ignition switch in LOCK position 

Release accumulator negative wire and wait for 1 minute 

plus 

Remove steering pillar shell 

Release the clock spring connection clips 

Remove the PAB trim cover, glove box (passengers’ side 

safety airbag is under the trim cover) 

Release passengers’ side safety airbag module connector 

clips 

Release all SRS safety airbag system unit connector clips 

Install back the accumulator negative wire,   

Place the ignition switch in ON position 

Is the potential of SRS safety airbag system unit connector 

clips stitch 5,6(grounding) above 9V? 

No    Replace wiring harness 

Safety airbag-15

 

Yes 

Present failure codes 
Replace SRS safety airbag system unit   
See he removal/installation of SRS 
safety airbag system unit 
History accumulated failure codes 
The end of failure diagnosis 

Place the ignition switch in LOCK position   
Release accumulator negative wire and wait for 1 minute 
plus 
Remove the left trim cover 
Shut off SRS safety airbag system unit translation 
connector clips 
Install back the accumulator negative wire, place the 
ignition switch in ON position 
Is the potential of SRS safety airbag system unit connector 
clips stitch 5,6(grounding) above 9V? 

No Replace 

wiring 

harness 

Drive side failure 

Failure code 
$9021 
$9022 
$9024 
$9025 

Driver’s side safety airbag failure (high or low resistance, shorting grounding, etc.) 

Test 

condition 

Warning 
If not correctly handled, the safety airbag module as well as pretension safety belt may possibly be trigged, released 
and tensioned, thus make serene damage to people. Therefore, please carefully read the repairing warning before 
trouble handling. Please take references in safety airbag system repairing warning   
Driver’s side safety airbag 
The resistance between the SRS safety airbag system connector clips connectors not within the designated scope 
SRS safety airbag system driver’s side airbag relative wiring harness shorting or shutoff 

Possible 

causes 

Driver’s side safety airbag module failure 
Clock spring internal failure 
Failure of circuit connector clips between clock spring and SRS safety airbag system electronic-control unit   
Shutoff or shorting of wiring harness between clock spring and SRS safety airbag system electronic-control unit. 
Misconnection of SRS safety airbag system driver’s side airbag generator connector clip 

Procedure 

Test 

Operation 

Normal 

Next step 

Check the clock spring   
Warning 
If not correctly handled, the safety airbag module may possibly be 
trigged and released thus make serene damage to people. Therefore, 
please carefully read the repairing warning before trouble handling. 
Please take references in safety airbag system repairing warning. 

Are the relative parts of clock spring normal? (The relation between 

stitches, unnecessary shutoff or shorting?) if the present clock spring can 
be replaced by a better one. 

Abnormal 

Replace the clock spring 
Take references in the 
removal/installation for 
safety airbag system and 
clock spring 

Replace the driver’s side 
safety airbag module 
T k

f

i

th

Confirm the failure in driver’s side safety airbag module or other parts. 
R l

th DAB

d l

ith b tt

Safety airbag-16

Yes Next 

step 

Confirm the failure in clock spring or other parts 
configure the special tools fuel and temperature diagnostic instrument 
at 2Ω position   
Install back the accumulator negative wire 
Place the ignition switch in ON place 
Any failure code in display? 

No 

Replace clock spring 
Take references in the removal 
and installation for safety airbag 
system and clock spring. 

Normal 

Replace SRS safety airbag 
system unit; take references in 
removal/installation of SRS 
safety airbag system unit. 

Check the wiring harness between clock spring and SRS safety airbag 
system electronic-control unit 
Place the ignition switch in LOCK position   
Release accumulator negative wire and wait for 1 minute plus 
Remove PAB trim cover, glove box (passengers’ side safety airbag is 
under the trim cover) 
Release the passengers’ side safety airbag module connector clip 
Release all SRS safety airbag system unit connector clips 
Check whether the following troubles are with the harness between 
connector clips terminals of SRS safety airbag system unit and clock 
spring  
Grounding  
Power-supply shorting 
Shutoff  
Is the previous wiring harness normal? 

Abnormal 

Replace the wire harness 

Normal Next 

step 

Check the clock spring connector clip 
Remove the steering pillar shell 
Release the clock spring connector clip 
Is the clock spring connector clip normal? 

Abnormal 

Replace the wiring harness or 
connector clips 
 

Normal Next 

step 

Check clock spring   
Remove clock spring   
Take references in removal/installation of safety airbag system as 
well as clock spring 
Check clock spring   
Take references in the test for safety airbag system and clock spring. 
Is the clock spring normal? 

Abnormal 

Replace clock spring 
Take references in the 
removal/installation of safety 
airbag system and clock spring. 

Normal Next 

step 

Check the wiring harness between clock spring and SRS safety airbag 
system electronic-control unit 
Place the ignition switch in LOCK position 
Release accumulator negative wire and wait for 1 minute plus 
Remove PAB trim cover, glove box (passengers’ side safety airbag is 
under the trim cover) 
Release the passengers’ side safety airbag module connector clip 
Release all SRS safety airbag system unit connector clips. 
Check whether the following troubles are with the harness between 
connector clips terminals of SRS safety airbag system unit and spring 
clock. 
Grounding  
Power-supply shorting 
Shutoff  
Is the previous harness normal? 

Abnormal 

Replace clock spring 
Take references in the 
removal/installation of safety 
airbag system, and clock spring 

 

 

 

 

 

 

 

Content   ..  92  93  94  95   ..