Dodge Durango (HB). Manual - part 1452

 

  Index      Dodge     Dodge Durango (HB) - service repair manual 2005 year

 

Search            

 

 

 

 

 

 

 

 

 

Content   ..  1450  1451  1452  1453   ..

 

 

Dodge Durango (HB). Manual - part 1452

 

 

HEATING & AIR CONDITIONING

TABLE OF CONTENTS

page

page

HVAC - ELECTRICAL DIAGNOSTICS. . . . . . . . . . . . 1

HVAC - SERVICE INFORMATION . . . . . . . . . . . . 322

HVAC - ELECTRICAL DIAGNOSTICS

TABLE OF CONTENTS

page

page

HVAC - ELECTRICAL DIAGNOSTICS

DIAGNOSIS AND TESTING

B100A–RECIRCULATION SWITCH

REQUEST INPUT CIRCUIT LOW (ATC) . . . . . . 4

B100D–FLOOR MODE SWITCH REQUEST

INPUT CIRCUIT LOW (ATC) . . . . . . . . . . . . . . . 5

B101C–TEMP DOWN SWITCH REQUEST

INPUT CIRCUIT LOW (ATC) . . . . . . . . . . . . . . . 6

B101F–POWER ON/OFF SWITCH REQUEST

INPUT CIRCUIT LOW (ATC) . . . . . . . . . . . . . . . 7

B102B–REAR FUNCTION CONTROL

SWITCH REQUEST INPUT CIRCUIT LOW
(ATC) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8

B102E–REAR BLEND REQUEST INPUT

CIRCUIT LOW (ATC) . . . . . . . . . . . . . . . . . . . . 9

B102E–REAR BLEND REQUEST INPUT

CIRCUIT LOW (MTC) . . . . . . . . . . . . . . . . . . . 13

B102F–REAR BLEND REQUEST INPUT

CIRCUIT HIGH (ATC) . . . . . . . . . . . . . . . . . . . 17

B102F–REAR BLEND REQUEST INPUT

CIRCUIT HIGH (MTC) . . . . . . . . . . . . . . . . . . 22

B103A–REAR MODE DOOR CONTROL

CIRCUIT/PERFORMANCE (ATC) . . . . . . . . . . 28

B103A–REAR MODE DOOR CONTROL

CIRCUIT/PERFORMANCE (MTC) . . . . . . . . . . 29

B103B–REAR MODE DOOR CONTROL

CIRCUIT LOW (ATC) . . . . . . . . . . . . . . . . . . . 30

B103B–REAR MODE DOOR CONTROL

CIRCUIT LOW (MTC) . . . . . . . . . . . . . . . . . . . 38

B103C–REAR MODE DOOR CONTROL

CIRCUIT HIGH (ATC) . . . . . . . . . . . . . . . . . . . 43

B103C–REAR MODE DOOR CONTROL

CIRCUIT HIGH (MTC) . . . . . . . . . . . . . . . . . . 46

B103D–REAR MODE DOOR CONTROL

CIRCUIT OPEN (ATC) . . . . . . . . . . . . . . . . . . 49

B103D–REAR MODE DOOR CONTROL

CIRCUIT OPEN (MTC) . . . . . . . . . . . . . . . . . . 53

B103E–REAR MODE DOOR TRAVEL

RANGE TOO SMALL (ATC & MTC) . . . . . . . . 57

B103F–REAR MODE DOOR TRAVEL RANGE

TOO LARGE (ATC & MTC) . . . . . . . . . . . . . . . 59

B104A–FLOOR/DEFROST MODE DOOR

TRAVEL RANGE TOO SMALL (ATC & MTC) . . 61

B104B–FLOOR/DEFROST MODE DOOR

TRAVEL RANGE TOO LARGE (ATC &
MTC) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63

B104C–BLEND DOOR CONTROL CIRCUIT/

PERFORMANCE (ATC) . . . . . . . . . . . . . . . . . 65

B104C–BLEND DOOR CONTROL CIRCUIT/

PERFORMANCE (ACTIVE) (MTC) . . . . . . . . . 66

B104D–BLEND DOOR CONTROL CIRCUIT

LOW (ATC) . . . . . . . . . . . . . . . . . . . . . . . . . . 67

B104D–BLEND DOOR CONTROL CIRCUIT

LOW (MTC) . . . . . . . . . . . . . . . . . . . . . . . . . . 71

B104E–BLEND DOOR CONTROL CIRCUIT

HIGH (ATC) . . . . . . . . . . . . . . . . . . . . . . . . . . 75

B104E–BLEND DOOR CONTROL CIRCUIT

HIGH (MTC) . . . . . . . . . . . . . . . . . . . . . . . . . . 78

B104F–BLEND DOOR CONTROL CIRCUIT

OPEN (ATC) . . . . . . . . . . . . . . . . . . . . . . . . . . 81

B104F–BLEND DOOR CONTROL CIRCUIT

OPEN (MTC) . . . . . . . . . . . . . . . . . . . . . . . . . 85

B105A–RECIRCULATION DOOR CONTROL

CIRCUIT HIGH (ATC) . . . . . . . . . . . . . . . . . . . 89

B105A–RECIRCULATION DOOR CONTROL

CIRCUIT HIGH (MTC) . . . . . . . . . . . . . . . . . . 92

B105B–RECIRCULATION DOOR CONTROL

CIRCUIT OPEN (ATC) . . . . . . . . . . . . . . . . . . 95

B105B–RECIRCULATION DOOR CONTROL

CIRCUIT OPEN (MTC) . . . . . . . . . . . . . . . . . . 99

B105C–RECIRCULATION DOOR TRAVEL

RANGE TOO SMALL (ATC & MTC) . . . . . . . . 103

B105D–RECIRCULATION DOOR TRAVEL

RANGE TOO LARGE (ATC & MTC) . . . . . . . 105

HB

HEATING & AIR CONDITIONING

24 - 1

B105F–CLIMATE CONTROL MOTOR(S)

COMMON 1 CONTROL CIRCUIT LOW
(ATC) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 107

B105F–CLIMATE CONTROL MOTOR(S)

COMMON 1 CONTROL CIRCUIT LOW
(MTC) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 112

B107E–AUXILIARY COOLANT PUMP

CONTROL CIRCUIT LOW (ATC) . . . . . . . . . . 119

B107E–AUXILIARY COOLANT PUMP

CONTROL CIRCUIT LOW (MTC) . . . . . . . . . 122

B108E–INFRARED TEMPERATURE

SENSOR INTERNAL (ATC) . . . . . . . . . . . . . . 125

B108F–AUTOMATIC TEMPERATURE

CONTROL SYSTEM PERFORMANCE
(ATC) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 127

B1001–A/C SWITCH REQUEST INPUT

CIRCUIT LOW (ATC & MTC) . . . . . . . . . . . . 129

B1004–PANEL MODE SWITCH REQUEST

INPUT CIRCUIT LOW (ATC) . . . . . . . . . . . . . 130

B1007–BI-LEVEL SWITCH REQUEST INPUT

CIRCUIT LOW (ATC) . . . . . . . . . . . . . . . . . . 131

B1010–MIX SWITCH REQUEST INPUT

CIRCUIT LOW (ATC) . . . . . . . . . . . . . . . . . . 132

B1013–DEFROST SWITCH REQUEST

INPUT CIRCUIT LOW (ATC) . . . . . . . . . . . . . 133

B1016–REAR DEFROST SWITCH REQUEST

INPUT CIRCUIT LOW (ATC & MTC) . . . . . . . 134

B1019–TEMP UP SWITCH REQUEST INPUT

CIRCUIT LOW (ATC) . . . . . . . . . . . . . . . . . . 135

B1022–BLOWER SPEED UP SWITCH

REQUEST INPUT CIRCUIT LOW (ATC) . . . . 136

B1025–BLOWER SPEED DOWN SWITCH

REQUEST INPUT CIRCUIT LOW (ATC) . . . . 137

B1027–REAR BLOWER CONTROL

REQUEST INPUT CIRCUIT/
PERFORMANCE (ATC) . . . . . . . . . . . . . . . . 138

B1031–EVAPORATOR FIN TEMPERATURE

SENSOR CIRCUIT LOW (ATC) . . . . . . . . . . . 144

B1031–EVAPORATOR FIN TEMPERATURE

SENSOR CIRCUIT LOW (MTC) . . . . . . . . . . 148

B1032–EVAPORATOR FIN TEMPERATURE

SENSOR CIRCUIT HIGH (ATC) . . . . . . . . . . 152

B1032–EVAPORATOR FIN TEMPERATURE

SENSOR CIRCUIT HIGH (MTC) . . . . . . . . . . 157

B1034–INFRARED TEMPERATURE SENSOR

INPUT CIRCUIT LOW . . . . . . . . . . . . . . . . . . 162

B1035–INFRARED TEMPERATURE SENSOR

INPUT CIRCUIT HIGH . . . . . . . . . . . . . . . . . 163

B1038–AUTO SWITCH REQUEST INPUT

CIRCUIT LOW (ATC) . . . . . . . . . . . . . . . . . . 164

B1040–PANEL MODE DOOR 1 CONTROL

CIRCUIT/PERFORMANCE (ATC) . . . . . . . . . 165

B1040–PANEL MODE DOOR 1 CONTROL

CIRCUIT/PERFORMANCE (MTC) . . . . . . . . . 166

B1041–PANEL MODE DOOR 1 CONTROL

CIRCUIT LOW (ATC) . . . . . . . . . . . . . . . . . . 167

B1041–PANEL MODE DOOR 1 CONTROL

CIRCUIT LOW (MTC) . . . . . . . . . . . . . . . . . . 171

B1042–PANEL MODE DOOR 1 CONTROL

CIRCUIT HIGH (ATC) . . . . . . . . . . . . . . . . . . 175

B1042–PANEL MODE DOOR 1 CONTROL

CIRCUIT HIGH (MTC) . . . . . . . . . . . . . . . . . 178

B1043–PANEL MODE DOOR 1 CONTROL

CIRCUIT OPEN (ATC) . . . . . . . . . . . . . . . . . 181

B1043–PANEL MODE DOOR 1 CONTROL

CIRCUIT OPEN (MTC) . . . . . . . . . . . . . . . . . 185

B1044–PANEL MODE DOOR 1 TRAVEL

RANGE TOO SMALL (ATC & MTC) . . . . . . . . 189

B1045–PANEL MODE DOOR 1 TRAVEL

RANGE TOO LARGE (ATC & MTC) . . . . . . . 191

B1046–FLOOR/DEFROST MODE DOOR

CONTROL CIRCUIT/PERFORMANCE
(ATC) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 193

B1046–FLOOR/DEFROST MODE DOOR

CONTROL CIRCUIT/PERFORMANCE
(MTC) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 194

B1047–FLOOR/DEFROST MODE DOOR

CONTROL CIRCUIT LOW (ATC) . . . . . . . . . . 195

B1047–FLOOR/DEFROST MODE DOOR

CONTROL CIRCUIT LOW (MTC) . . . . . . . . . 199

B1048–FLOOR/DEFROST MODE DOOR

CONTROL CIRCUIT HIGH (ATC) . . . . . . . . . 203

B1048–FLOOR/DEFROST MODE DOOR

CONTROL CIRCUIT HIGH (MTC) . . . . . . . . . 206

B1049–FLOOR/DEFROST MODE DOOR

CONTROL CIRCUIT OPEN (ATC) . . . . . . . . . 209

B1049–FLOOR/DEFROST MODE DOOR

CONTROL CIRCUIT OPEN (MTC) . . . . . . . . 213

B1050–BLEND DOOR TRAVEL RANGE TOO

SMALL (ATC & MTC) . . . . . . . . . . . . . . . . . . 217

B1051–BLEND DOOR TRAVEL RANGE TOO

LARGE (ATC & MTC) . . . . . . . . . . . . . . . . . . 219

B1052–REAR BLEND DOOR CONTROL

CIRCUIT/PERFORMANCE (ATC) . . . . . . . . . 221

B1052–REAR BLEND DOOR CONTROL

CIRCUIT/PERFORMANCE (MTC) . . . . . . . . . 221

B1053–REAR BLEND DOOR CONTROL

CIRCUIT LOW (ATC) . . . . . . . . . . . . . . . . . . 222

B1053–REAR BLEND DOOR CONTROL

CIRCUIT LOW (MTC) . . . . . . . . . . . . . . . . . . 230

B1054–REAR BLEND DOOR CONTROL

CIRCUIT HIGH (ATC) . . . . . . . . . . . . . . . . . . 234

B1054–REAR BLEND DOOR CONTROL

CIRCUIT HIGH (MTC) . . . . . . . . . . . . . . . . . 237

B1055–REAR BLEND DOOR CONTROL

CIRCUIT OPEN (ATC) . . . . . . . . . . . . . . . . . 240

B1055–REAR BLEND DOOR CONTROL

CIRCUIT OPEN (MTC) . . . . . . . . . . . . . . . . . 244

B1056–REAR BLEND DOOR TRAVEL

RANGE TOO SMALL (ATC & MTC) . . . . . . . . 248

B1057–REAR BLEND DOOR TRAVEL

RANGE TOO LARGE (ATC & MTC) . . . . . . . 250

B1058–RECIRCULATION DOOR CONTROL

CIRCUIT/PERFORMANCE (ATC) . . . . . . . . . 252

B1058–RECIRCULATION DOOR CONTROL

CIRCUIT/PERFORMANCE (MTC) . . . . . . . . . 253

24 - 2

HVAC - ELECTRICAL DIAGNOSTICS

HB

B1059–RECIRCULATION DOOR CONTROL

CIRCUIT LOW (ATC) . . . . . . . . . . . . . . . . . . 254

B1059–RECIRCULATION DOOR CONTROL

CIRCUIT LOW (MTC) . . . . . . . . . . . . . . . . . . 258

B1060–CLIMATE CONTROL MOTOR(S)

COMMON 1 CONTROL CIRCUIT HIGH
(ATC) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 262

B1060–CLIMATE CONTROL MOTOR(S)

COMMON 1 CONTROL CIRCUIT HIGH
(MTC) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 265

B1063–CLIMATE CONTROL MOTOR(S)

COMMON 2 CONTROL CIRCUIT LOW
(ATC) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 268

B1064–CLIMATE CONTROL MOTOR(S)

COMMON 2 CONTROL CIRCUIT HIGH
(ATC) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 272

B1067–CLIMATE CONTROL MOTOR(S)

COMMON 3 CONTROL CIRCUIT LOW
(ATC) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 275

B1068–CLIMATE CONTROL MOTOR(S)

COMMON 3 CONTROL CIRCUIT HIGH
(ATC) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 279

B1070–REAR BLOWER CONTROL CIRCUIT

HIGH (ATC) . . . . . . . . . . . . . . . . . . . . . . . . . 282

B1079–CLIMATE CONTROL COOL DOWN

TEST EXCESSIVE TIME (ATC & MTC) . . . . . 286

B1080–AUXILIARY COOLANT PUMP

CONTROL CIRCUIT OPEN (ATC) . . . . . . . . . 288

B1080–AUXILIARY COOLANT PUMP

CONTROL CIRCUIT OPEN (MTC) . . . . . . . . 292

B1090–ACTUATOR PULSE COUNT

PERFORMANCE (ATC & MTC) . . . . . . . . . . . 296

B2214–(HVAC) CLIMATE CONTROL

INTERNAL (ATC & MTC) . . . . . . . . . . . . . . . 298

B2310–REAR WASHER SWITCH INPUT

CIRCUIT LOW (ATC & MTC) . . . . . . . . . . . . 299

U0019–CAN B BUS (ATC)

. . . . . . . . . . . . . . 300

U0019–CAN B BUS (MTC)

. . . . . . . . . . . . . . 303

U0141–LOST COMMUNICATION WITH

FRONT CONTROL MODULE (ATC & MTC) . 306

U0155–LOST COMMUNICATION WITH

CLUSTER/CCN (ATC & MTC) . . . . . . . . . . . . 307

U0156–LOST COMMUNICATION WITH EOM

(ATC) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 308

DTC SET DURING ROUTINE - TEST NOT

PASSED (ATC & MTC) . . . . . . . . . . . . . . . . . 309

BLOWERS NOT ON HIGH - TEST

NOT RUN . . . . . . . . . . . . . . . . . . . . . . . . . . . 310

REFRIGERANT TEMPERATURE SENSOR

ERROR (ATC & MTC) . . . . . . . . . . . . . . . . . . 311

*HVAC SYSTEM TEST (ATC)

. . . . . . . . . . . . 312

*HVAC SYSTEM TEST (MTC)

. . . . . . . . . . . 316

SCHEMATICS AND DIAGRAMS

. . . . . . . . . . . 319

HVAC - ELECTRICAL DIAGNOSTICS

DIAGNOSIS AND TESTING

HB

HVAC - ELECTRICAL DIAGNOSTICS

24 - 3

B100A–RECIRCULATION SWITCH REQUEST INPUT CIRCUIT LOW (ATC)

For a complete wiring diagram Refer to Section 8W.

When Monitored:
With the ignition on.

Set Condition:
If the Recirculation mode switch is stuck in a pushed position for more than two minutes. This DTC has a
maturing time of two minutes and a de-maturing time of two seconds. If the DTC’s status changes from active
to stored it will stay in memory for 100 ignition cycles.

Possible Causes

OBJECT HOLDING SWITCH IN A PUSHED POSITION

A/C HEATER CONTROL

Theory of Operation

The switch input changes when the switch is pushed down. An active DTC indicates that the switch is stuck in a
pushed position. A stored DTC indicates that the switch was stuck in a pushed position for more than two minutes,
but has since returned to its normal state.

NOTE: This DTC must be active for the results of this test to be valid. Do not perform this test if this DTC
is stored. Refer to HVAC System Test (ATC) for stored DTC test procedures.

Diagnostic Test

1.

INSPECT FOR OBJECT HOLDING SWITCH IN A PUSHED POSITION

Inspect the A/C Heater Control for an object holding the switch in a pushed position. If present, remove the object.

Turn the ignition on.

With the scan tool, erase HVAC DTCs.

Turn the ignition off, wait 10 seconds, and then turn the ignition on.

Wait two minutes, then with the scan tool, read HVAC DTCs.

Does the scan tool display active: B100A–RECIRCULATION SWITCH REQUEST INPUT CIRCUIT LOW?

Yes

>> Replace the A/C Heater Control in accordance with the Service Information.

Perform BODY VERIFICATION TEST – VER 1. (Refer to BODY VERIFICATION TEST – VER 1).

No

>> Perform BODY VERIFICATION TEST – VER 1. (Refer to BODY VERIFICATION TEST – VER 1).

24 - 4

HVAC - ELECTRICAL DIAGNOSTICS

HB

 

 

 

 

 

 

 

Content   ..  1450  1451  1452  1453   ..