Symptom:
*GLOVE BOX LAMP INOPERATIVE
POSSIBLE CAUSES
INOPERATIVE BULB
GLOVE BOX LAMP DRIVER CIRCUIT SHORT TO VOLTAGE
GLOVE BOX LAMP SWITCH
CENTRAL TIMER MODULE
TEST
ACTION
APPLICABILITY
1
Remove and inspect the inoperative bulb.
Is the inspected bulb OK?
All
Yes
→
Go To
2
No
→
Replace the inoperative bulb.
Perform BODY VERIFICATION TEST - VER 1.
2
Disconnect the Glove Box Lamp Switch harness connector.
Disconnect the Central Timer Module harness connector
Measure the resistance of the Glove Box Lamp Driver Circuit between the Central
Timer Module harness connector and the Glove Box Lamp Switch harness connector.
Is the resistance below 5.0 ohms?
All
Yes
→
Go To
3
No
→
Repair the Glove Box Lamp Driver Circuit for a short to voltage.
Perform BODY VERIFICATION TEST - VER 1.
3
Disconnect the Glove Box Lamp Switch harness connector.
Disconnect the Central Timer Module harness connector.
Measure the resistance between the Glove Box Lamp Switch harness connector and
the Central Timer Module harness connector.
Is the resistance below 5.0 ohms?
All
Yes
→
Replace the Central Timer Module.
Perform BODY VERIFICATION TEST - VER 1.
No
→
Replace the Glove Box Lamp Switch
Perform BODY VERIFICATION TEST - VER 1.
245