Symptom: DRIVER SQUIB SHORT TO GROUND - ACTIVE When Monitored and Set Condition: DRIVER SQUIB SHORT TO GROUND - ACTIVE When Monitored: When the ignition is on, the ACM monitors the voltage of the Driver Squib circuits. Set Condition: The ACM has detected a short to ground in the Driver Squib circuits. POSSIBLE CAUSES DRIVER AIRBAG SHORT TO GROUND CLOCKSPRING, CIRCUITS SHORT TO GROUND DRIVER AIRBAG LINE 1 SHORT TO GROUND DRIVER AIRBAG LINE 2 SHORT TO GROUND ACM, DRIVER AIRBAG SHORT TO GROUND TEST ACTION APPLICABILITY 1 NOTE: Ensure that the battery is fully charged. t, read active DTCs. Does the DRB show DRIVER SQUIB SHORT TO GROUND? All Yes → No → Replace the Driver Airbag. NOTE: When reconnecting Airbag system components, the ignition must be 41 AIRBAG |