P0750-LR SOLENOID CIRCUIT (CONTINUED) 5. (T20) LR SOLENOID CONTROL CIRCUIT SHORT TO GROUND Measure the resistance between ground and the (T20) LR Solenoid Is the resistance below 5.0 ohms? Yes >> Repair the (T20) LR Solenoid Control circuit for a short to ground. Perform 42RLE TRANSMISSION VERIFICATION TEST - No >> Go To 6 6. (T20) LR SOLENOID CONTROL CIRCUIT SHORT TO VOLTAGE Remove the Transmission Control Relay. NOTE: Check connectors - Clean/repair as necessary. Ignition on, engine not running. Measure the voltage of the (T20) LR Solenoid Control circuit. Is the voltage above 0.5 volts? Yes >> Repair the (T20) LR Solenoid Control circuit for a short to voltage. Perform 42RLE TRANSMISSION VERIFICATION TEST - No >> Go To 8 21 - 144 AUTOMATIC TRANSMISSION 42RLE - ELECTRICAL DIAGNOSTICS ND |