DAF CF65, CF75, CF85 Series . Manual - part 1184

 

  Index      DAF     DAF CF65, CF75, CF85 Series - service repair manual

 

Search            

 

 

 

 

 

 

 

 

 

Content   ..  1182  1183  1184  1185   ..

 

 

DAF CF65, CF75, CF85 Series . Manual - part 1184

 

 

©

 200423

1-1

Threaded connections

THREADED CONNECTIONS

ΧΦ85 series

2

1. THREADED CONNECTIONS

1.1 GENERAL

The components may have threaded connections 
that have been treated with lubricant (dipped 
threaded connection). Galvanised bolts and nuts 
are wax dipped in the factory. Black annealed 
and phosphatised bolts and nuts are oil dipped. 
The advantage of using dipped nuts and bolts is 
that friction during tightening is reduced, so that 
the specified pre-tension force can be accurately 
obtained. The tightening torque can be reduced 
while the pre-tension force remains the same.

To achieve a small spread in the pre-tension 
force, the dipped threaded connection must be 
tightened accurately.
Therefore, always use a reliable torque wrench 
that provides a high degree of accuracy.

Note:
Have torque wrenches regularly inspected and 
calibrated.

Re-use of fasteners (bolt/nut/threaded end)
1.

Clean the thread (take particular care to 
remove locking compound residues) and the 
clamping faces

2.

Check the thread for damage. 
To do so, manually screw a new nut/bolt onto 
the thread to be checked. 
If the new nut/bolt cannot be fully hand-
screwed onto the entire thread of the 
fastener to be checked, the fastener is not 
allowed to be re-used. 

3.

Apply one drop of engine oil to the upper turn 
of the bolt (threaded end)/lower turn of the 
nut and one drop to the clamping faces 
(other lubricants are not allowed).

4.

If a locking compound has been specified, oil 
should not be applied to the thread.

THREADED CONNECTIONS

1-2

©

 200423

Threaded connections

2

ΧΦ85 series

The following applies to all threaded 
connections (for both new and used 
vehicles):
-

in the case of standard connections, apply 
the lubricant before fitting, and (re)tighten in 
accordance with the standard for dipped 
bolts;

-

in the case of special connections, apply the 
lubricant before fitting, and (re)tighten in 
accordance with the values specified in the 
instructions.

The instructions for using lubricants also apply to 
new bolts from the warehouse. Dry threaded 
connections may not be used because of their 
highly variable friction coefficients.

Please consult the workshop manual 
for the specified tightening torque.

}

FLUIDS, OIL AND LUBRICANTS

2

©

 200423

Contents

3

ΧΦ85 series

 

 

 

 

 

 

 

Content   ..  1182  1183  1184  1185   ..