© 200424 9-1 Hydraulic lifting gear TECHNICAL DATA ΧΦ65/75/85 series 8 0 9. HYDRAULIC LIFTING GEAR 9.1 GENERAL Cut-out pressure, pressure switch 160 bar Pre-set value, pressure relief valve 180 bar Maximum admissible system pressure 200 bar Test pressure, lifting cylinder 220 bar Delivery line while lifting Line connection B Delivery line while lowering Line connection A (The characters are printed on the pump unit) Safety device Once the trailing axle has been lowered, it can only be lifted again after approx. 2.5 minutes. If the control switch is put into the "lifting" position before approx. 2.5 minutes has elapsed, the lifting gear will not be activated and the time relay will be reset. In that case you will have to wait about another 2.5 minutes before the trailing axle can be lifted. |