DAF LF45, LF55 Series. Manual - part 32

 

  Index      DAF     DAF LF45, LF55 Series - service repair manual

 

Search            

 

 

 

 

 

 

 

 

 

Content   ..  30  31  32  33   ..

 

 

DAF LF45, LF55 Series. Manual - part 32

 

 

©

2-1

System inspection with DAVIE XD

EMAS

DAVIE XD diagnostics manual 

5

2. SYSTEM INSPECTION WITH DAVIE XD

2.1 GENERAL

When changes are made to the EMAS system or 

when it is opened, the system must be calibrated.

2.2 "CALIBRATION" MENU

The "Calibration" menu is divided into several 

tests:

-

Air  test

-

Bleeding

-

Releasing the pressure

-

Hydraulic test

-

Electric test

-

Complete calibration

Air test
This test is used to check whether there is air in 

the EMAS system.

If so, the EMAS system must be bled.

Bleeding
With this test, an air test will be carried out first. If 

air is found in the EMAS system, the trailing axle 

will be steered back and forth and there is a 

possibility of releasing air. Afterwards another air 

test will be carried out to check whether there is 

still air in the system.

If air is still present, the above routine is repeated.

Releasing the pressure
If centring circuit components or components 

connected to the centring circuit need to be 

removed, the pressure in the centring circuit must 

be released. When this test is selected, the 

pressure in the centring circuit will be released by 

opening and closing various valves.

Hydraulic test
Checking the hydraulic system:

With this test it is checked whether the various 

valves are properly steered and/or the system 

lines are properly connected. Furthermore, the 

central position of the steering cylinder is also 

calibrated.

EMAS

2-2

©

System inspection with DAVIE XD

5

DAVIE XD diagnostics manual

Electric test
Checking the electric system:

With this test it is checked whether all sensors 

and valves of the EMAS system are connected; 

furthermore, the resistors of the coils are 

checked.

Complete calibration
The complete calibration consists of:

-

Electric test

-

Hydraulic test

-

Air  test

The sensors are calibrated in between.

This complete calibration is necessary after 

virtually any work is carried out on the system.

©

1