8 DIAGNOSIS Hydraulic lifting gear 4-2 FAULT: TRAILING AXLE IS LIFTED PARTIALLY, PUMP MOTOR CONTINUES TO OPERATE Possible cause Remedy Not enough oil in the reservoir Check oil level and top up, if necessary Opening pressure of pressure-relief valve too Check the opening pressure of the The 4/2 valve is leaking Check the system pressure and subsequently Insufficient pump delivery due to leakage Check the system pressure, the pump and the FAULT: PUMP MOTOR CONTINUES TO OPERATE WHILE THE TRAILING AXLE HAS BEEN FULLY LIFTED OR LOWERED Possible cause Remedy Pressure-relief valve setting too low Check the opening pressure of the Pressure switch is not functioning Check the pressure switch and the wiring Fault in electrical circuit Check electrical circuit FAULT: TRAILING AXLE DOES NOT LOWER, PUMP MOTOR IS NOT RUNNING Possible cause Remedy Fault in electrical circuit Check electrical circuit FAULT: TRAILING AXLE DOES NOT LOWER, PUMP MOTOR IS OPERATING BUT IS SWITCHED OFF IMMEDIATELY Possible cause Remedy 2/2 valve is not functioning Check whether the 2/2 valve is activated The 2/2 and 4/2 valve connectors have been Check the connection using the wire numbers Piping kinked Check piping 1 ǹ 0001 |