© 200438 1-3 Airtronic (ACH-EA) fault codes AIRTRONIC (ACH-EA) DAVIE XD diagnostics manual 9 7-1 Short circuit to earth or short circuit to supply of - Cab heater does not start Internal fault in fuel metering pump (B122) 7-2 Interruption on pin 4 and/or 9 of the ECU (D871), - Cab heater does not start Internal fault in fuel metering pump (B122) 8-1 Short circuit to earth or short circuit to supply of - Cab heater does not start Internal fault in fan (B305) 8-2 Interruption of cab heater fan (B305) on pins BM1 - Cab heater does not start Internal fault in fan (B305) 8-3 Cab heater fan (B305) speed deviation due to: blocked vent - missing solenoid in electric motor - defective ECU (D871) - Cab heater fails during operation 9-1 Short circuit to earth or short circuit to supply of - Cab heater does not start 9-2 Interruption of glow filament (B168) on pin GS1 - Cab heater does not start 10-0 Cab heater gets overheated too often due to: clogged hot air pipes - defective overheating sensor (combisensor - insufficient supply of inlet air - Cab heater fails during operation 10-4 ACH-EA safety function switched on as a result too many overheatings - The ECU is blocked 12-1 Short circuit to earth or short circuit to supply of - Cab heater does not start - Cab heater does not switch on or off at the Internal fault in thermostat unit (E566) or timer 12-2 Interruption of temperature unit (F566) on pin 10 - Cab heater does not start - Cab heater does not switch on or off at the Internal fault in thermostat unit (E566) or timer 13-1 Short circuit to earth or short circuit to supply of - Cab heater does not start or fails during Fault code Fault code description with possible cause Symptom |