© 200438 1-7 Hydronic 10 (ACH-EW) fault codes HYDRONIC 10 (ACH-EW) DAVIE XD diagnostics manual 6 10-4 ACH-EW safety function switched on as a result too many overheatings - Cab heater fails. The ECU blocks after 3 11-1 Short circuit in coolant circulation pump on pins 3 - Cab heater does not start or fails during 11-2 Open connection of coolant circulation pump on - Cab heater does not start or fails during 13-1 Overheating sensor short circuit on pins 11 and - Cab heater does not start or fails during 13-2 Open connection of overheating sensor on pins - Cab heater does not start or fails during 13-3 Difference between value of overheating sensor poor flow of coolant - coolant shortage - use of intarder - Cab heater does not start or fails during 15-1 Short circuit in wiring "signal ACH-EW on" to pin - No interior detection alarm system (ALS-S) Fault code Fault code description with possible cause Symptom |