Symptom: *POWER SLIDING DOOR INOPERATIVE POSSIBLE CAUSES DTC’S PRESENT MODULE RESPONSE INTERMITTENT PROBLEM SYSTEM TESTS TEST ACTION APPLICABILITY 1 With the DRBIII t check for response from the Body Computer and the Power Sliding Door Modules All Yes → Go To 2 No → Refer to symptom list for problems related to COMMUNICA- TION. 2 With the DRBIII t, read DTCs in POWER SLIDING DOOR and BODY COMPUTER. Are any Power Sliding Door related codes present? All Yes → Refer to symptom list for problems related to POWER SLIDING DOORS. No → Go To 3 3 This test will determine what inhibited the Power Sliding Door from operating t, select POWER SLIDING DOOR, MISCELLANEOUS, LAST INHIBIT MONITOR. t display any INHIBIT REASONS? All Yes → Check for any binding conditions or other restrictions that may prevent proper operation. Using the wiring diagram/schematic as No → Go To 4 4 Ensure the sliding door is fully closed before proceeding. t select SYSTEM TEST. Perform the Open, Close, Latch Cinch, Latch Release and Relay tests. All Yes → Using the wiring diagram/schematic as a guide, inspect the wiring and connectors. No → Test Complete. 1097 POWER DOORS - SLIDING |