Chrysler RG Voyager. Manual - part 246

 

  Index      Chrysler     Chrysler RG Voyager - service repair manual 2005 year

 

Search            

 

 

 

 

 

 

 

 

 

Content   ..  244  245  246  247   ..

 

 

Chrysler RG Voyager. Manual - part 246

 

 

TEST

ACTION

APPLICABILITY

5

Using the 9001 RF Detector, follow the instructions on the back of the tester and test
the transmitter several times.
Does the signal strength measure

9STRONG9?

All

Yes

→ Go To 6

No

→ Check and replace the battery if it is under 3.2 volts and retest the

transmitter. If the battery is okay, replace the transmitter.
Perform SKREEM VERIFICATION TEST - VER 1A.

6

With the DRBIII

t, select THEFT ALARM, SKIM then PROGRAM NEW KEY and

follow the instructions on the screen.
Exit PROGRAM NEW KEY.
Activate the Door Locks using the RKE Transmitter.
Did the door locks respond properly to the RKE transmitter commands?

All

Yes

→ Repair complete.

No

→ Replace the Sentry Key RemotE Entry Module.

Perform SKREEM VERIFICATION TEST - VER 1A.

953

POWER DOOR LOCKS/RKE

*REMOTE KEYLESS ENTRY INOPERATIVE —

Continued

Symptom:

*RIGHT CYLINDER LOCK SWITCH INOPERATIVE

POSSIBLE CAUSES

DTC PRESENT

BODY CONTROL MODULE - RIGHT CYLINDER LOCK SWITCH VOLTAGE LOW

CYLINDER LOCK SWITCH GROUND OPEN

CYLINDER LOCK SWITCH MUX OPEN

CYLINDER LOCK SWITCH OPEN

CYLINDER LOCK SWITCH MUX SHORT TO VOLTAGE

BODY CONTROL MODULE - RIGHT CYLINDER LOCK SWITCH MUX SHORT TO VOLTAGE

TEST

ACTION

APPLICABILITY

1

NOTE: When this code is present, the VTSS indicator will stay on solid during the
arming process.
With the DRBIII

t, record and erase DTC’s.

With the DRBIII

t, read DTCs.

Remove the key and operate the door locks several times from the Right Cylinder
Lock Switch while monitoring the DRBIII

t.

Wait 10 seconds.
With the DRBIII

t, read DTCs.

Are there any Power Door Lock related DTC’s?

All

No

→ Go To 2

Yes

→ Refer to symptom list for problems related to POWER DOOR

LOCKS.
Perform BODY VERIFICATION TEST - VER 1.

2

With the DRBIII

t in Sensors, read the RIGHT CYL LOCK SW voltage.

Does the DRBIII

t display 4.2 volts or greater?

All

Yes

→ Go To 3

No

→ Disconnect the BCM harness connector(s). Check connectors -

Clean/repair as necessary. If okay, replace the Body Control
Module.
Perform BODY VERIFICATION TEST - VER 1.

3

Disconnect the Right Cylinder Lock Switch connector.
Using a 12-volt test light connected to 12-volts, check the Ground circuit.
Does the test light illuminate brightly?

All

Yes

→ Go To 4

No

→ Repair the Ground circuit for an open.

Perform BODY VERIFICATION TEST - VER 1.

954

POWER DOOR LOCKS/RKE

TEST

ACTION

APPLICABILITY

4

Disconnect the Right Cylinder Lock Switch connector.
Measure the voltage between Cylinder Lock Switch Mux circuit and ground.
Select the voltage present.

All

Below 4.2 volts.

Repair the Cylinder Lock Switch Mux circuit for an open.
Perform BODY VERIFICATION TEST - VER 1.

Between 4.3 and 5.2 volts.

Replace the Cylinder Lock Switch.
Perform BODY VERIFICATION TEST - VER 1.

Above 5.3 volts.

Go To

5

5

Disconnect the Right Cylinder Door Lock Switch connector.
Disconnect the Body Control Module C3 connector.
NOTE: Check connectors - Clean/repair as necessary.
Turn the ignition on.
Measure the voltage between Right Cylinder Lock Switch Mux circuit and Ground in
the harness connector.
Is there any voltage present?

All

Yes

→ Repair the Cylinder Lock Switch Mux circuit for a short to

voltage.
Perform BODY VERIFICATION TEST - VER 1.

No

→ Replace the Body Control Module.

Perform BODY VERIFICATION TEST - VER 1.

955

POWER DOOR LOCKS/RKE

*RIGHT CYLINDER LOCK SWITCH INOPERATIVE —

Continued

Symptom:

AMBIENT TEMPERATURE SENSOR CIRCUIT OPEN

When Monitored and Set Condition:

AMBIENT TEMPERATURE SENSOR CIRCUIT OPEN

When Monitored:

Whenever the Power Liftgate Module is awake.

Set Condition:

If the module senses a resistance above 382K ohms on the Liftgate

Temperature Sensor Signal circuit, this code will set. The normal range for the sensor is
1.2K to 382K ohms. At room temperature (68° F) the resistance will be between 11.2 K and
13.5K ohms.

POSSIBLE CAUSES

DTC PRESENT

POWER LIFTGATE MODULE - TEMPERATURE SENSE OPEN

LIFTGATE TEMPERATURE SENSOR SIGNAL WIRE OPEN

GROUND WIRE OPEN

LIFTGATE TEMPERATURE SENSOR

TEST

ACTION

APPLICABILITY

1

With the DRBIII

t, record and erase DTC’s.

Turn the ignition off, wait 10 seconds, then turn the ignition on.
Operate the liftgate several times.
With the DRBIII

t, read DTCs.

Does the DRBIII

t display AMBIENT TEMPERATURE SENSOR CIRCUIT OPEN?

All

Yes

→ Go To 2

No

→ Using the wiring diagram/schematic as a guide, inspect the

wiring and connectors for an intermittent condition.
Perform BODY VERIFICATION TEST - VER 1.

2

Remove the power liftgate motor trim panel.
Disconnect the Power Liftgate Module C2 connector.
Measure the resistance of the liftgate Temperature Sensor Signal circuit to the
Ground circuit (cavity 20) in the PLG C2 connector.
Is the resistance between 1.2k and 382K ohms?

All

Yes

→ Replace the Power Liftgate Module.

Perform BODY VERIFICATION TEST - VER 1.

No

→ Go To 3

956

POWER DOORS - LIFTGATE

 

 

 

 

 

 

 

Content   ..  244  245  246  247   ..