TEST

ACTION

APPLICABILITY

3

Turn the ignition off.
Disconnect the right front park lamp connector.
Turn the ignition on.
Turn the Park Lamps on.
Using a 12-volt test light connected to ground, check the Park Lamp Output circuit.
Does the test light illuminate brightly?

All

Yes

→ Replace the Park Lamp.

Perform BODY VERIFICATION TEST - VER 1.

No

→ Go To 4

4

Turn the ignition off.
Check the IPM Park Lamp Fuse #3.
Is the Fuse open?

All

Yes

→ Replace the Park Lamp Fuse #3.

Perform BODY VERIFICATION TEST - VER 1.

No

→ Go To 5

5

Turn the ignition off.
Install a known good relay in place of the Park Lamp Relay.
Turn the Park Lamps on.
Do the Park Lamps operate normally?

All

Yes

→ Replace the Park Lamp Relay.

Perform BODY VERIFICATION TEST - VER 1.

No

→ Go To 6

6

Turn the ignition off.
Disconnect the IPM harness connector.
Measure the resistance of the Park Lamp Output circuit to ground.
Is the resistance above 5.0 ohms?

All

Yes

→ Repair the Park Lamp Output circuit for an open condition.

Perform BODY VERIFICATION TEST - VER 1.

No

→ Go To 7

7

Turn the ignition off.
Remove the Park Lamp Relay.
Measure the voltage of the Fused B+ circuit of the Park Lamp Relay.
Is the voltage above 10.0 volts?

All

Yes

→ Replace the Front Control Module.

Perform BODY VERIFICATION TEST - VER 1.

No

→ Replace the Intelligent Power Module.

Perform BODY VERIFICATION TEST - VER 1.

629

EXTERIOR LIGHTING

RIGHT SIDE PARK LAMP OPEN —

Continued

Symptom:

TURN SIGNAL SWITCH INPUT OPEN

When Monitored and Set Condition:

TURN SIGNAL SWITCH INPUT OPEN

When Monitored:

Ignition on.

Set Condition:

When voltage is below 4.8 volts.

POSSIBLE CAUSES

INTERMITTENT CONDITION

MULTIFUNCTION SWITCH

TURN SIGNAL SWITCH MUX CIRCUIT OPEN

MULTIFUNCTION SWITCH MUX RETURN CIRCUIT OPEN

BODY CONTROL MODULE

TEST

ACTION

APPLICABILITY

1

Turn the ignition on.
With the DRBIII

t, clear all BCM DTC’s.

Actuate the turn signals.
With the DRBIII

t, read the DTC information.

Does the DRBIII

t read: Turn Signal Switch Input Open?

All

Yes

→ Go To 2

No

→ The condition that caused the symptom is currently not present.

Inspect the related wiring for a possible intermittent condition.
Look for any chafed, pierced,pinched, or partially broken wires.
Perform BODY VERIFICATION TEST - VER 1.

2

Turn the ignition off.
Disconnect the Multifunction Switch harness connector.
Connect a jumper wire between the Turn Signal Switch MUX circuit and the
Multifunction Switch MUX Return circuit in the Multifunction Switch connector.
Turn the ignition on.
With the DRBIII

t, read the Multifunction Switch voltage.

Is the display voltage below 0.5 volts?

All

Yes

→ Replace the Multifunction Switch.

Perform BODY VERIFICATION TEST - VER 1.

No

→ Go To 3

630

EXTERIOR LIGHTING

TEST

ACTION

APPLICABILITY

3

Turn the ignition off.
Disconnect the applicable Body Control Module harness connector.
Disconnect the Multifunction Switch harness connector.
Measure the resistance of the Turn Signal Switch MUX circuit from the Body Control
Module connector to the Multifunction Switch harness connector.
Is the resistance above 5.0 ohms?

All

Yes

→ Repair the Turn Signal Switch MUX circuit for an open.

Perform BODY VERIFICATION TEST - VER 1.

No

→ Go To 4

4

Turn the ignition off.
Disconnect the applicable Body Control Module harness connector.
Disconnect the Multifunction Switch harness connector.
Measure the resistance of the Multifunction Switch MUX Return circuit from the
Body Control Module connector to the Multifunction Switch harness connector.
Is the resistance above 5.0 ohms?

All

Yes

→ Repair the Multifunction Switch MUX Return circuit for an open.

Perform BODY VERIFICATION TEST - VER 1.

No

→ Replace the Body Control Module.

Perform BODY VERIFICATION TEST - VER 1.

631

EXTERIOR LIGHTING

TURN SIGNAL SWITCH INPUT OPEN —

Continued

Symptom:

TURN SIGNAL SWITCH INPUT SHORT

When Monitored and Set Condition:

TURN SIGNAL SWITCH INPUT SHORT

When Monitored:

Ignition on.

Set Condition:

When Input voltage falls below 0.196 volts for 62.5 msec..

POSSIBLE CAUSES

INTERMITTENT CONDITION

MULTIFUNCTION SWITCH

TURN SIGNAL SWITCH MUX CIRCUIT SHORT TO GROUND

TURN SIGNAL SWITCH MUX SHORT TO MUX RETURN CIRCUIT.

MULTIFUNCTION SWITCH MUX RETURN CIRCUIT SHORT TO GROUND

BODY CONTROL MODULE

TEST

ACTION

APPLICABILITY

1

Turn the ignition on.
With the DRBIII

t, clear all BCM DTC’s.

Actuate the Turn Signals on.
With the DRBIII

t, read the DTC information.

Does the DRBIII

t read: Turn Signal Switch Input Short?

All

Yes

→ Go To 2

No

→ The condition that caused the symptom is currently not present.

Inspect the related wiring for a possible intermittent condition.
Look for any chafed, pierced,pinched, or partially broken wires.
Perform BODY VERIFICATION TEST - VER 1.

2

Turn the ignition off.
Disconnect the Multifunction Switch harness connector.
Turn the ignition on.
With the DRBIII

t, read the Multifunction Switch voltage.

Is the voltage above 4.8 volts?

All

Yes

→ Replace the Multifunction Switch.

Perform BODY VERIFICATION TEST - VER 1.

No

→ Go To 3

3

Turn the ignition off.
Disconnect the Body Control Module harness connector.
Disconnect the Multifunction Switch harness connector.
Measure the resistance between the Turn Signal Switch MUX circuit and ground.
Is the resistance below 5.0 ohms?

All

Yes

→ Repair the Turn Signal Switch MUX circuit for a short to ground.

Perform BODY VERIFICATION TEST - VER 1.

No

→ Go To 4

632