Symptom: INCOMPLETE POWER CLOSE - VOLTAGE BELOW MINIMUM When Monitored and Set Condition: INCOMPLETE POWER CLOSE - VOLTAGE BELOW MINIMUM LEVEL When Monitored: Whenever the power liftgate is performing a power close operation. Set Condition: The PLG Module detects that the voltage is below 9.5 volts during the power close operation. POSSIBLE CAUSES DTC PRESENT MODULE VOLTAGE LOW BINDING LIFTGATE DRB OPERATING VOLTAGE LOW PLG MODULE - HIGH RESISTANCE POWER LIFTGATE DRIVE MOTOR TEST ACTION APPLICABILITY 1 With the DRBIII t, record and erase DTC’s. Turn the ignition off, wait 10 seconds, then turn the ignition on. t, read DTCs. Does the DRBIII t display INCOMPLETE POWER CLOSE - VOLTAGE BELOW MINIMUM LEVEL? All Yes → Go To 2 No → Using the wiring diagram/schematic as a guide, inspect the wiring and connectors for an intermittent condition. Operate the 2 Examine the liftgate for proper fit and alignment, or anything that would cause an All Yes → Refer to Service information for the related symptom(s). Perform BODY VERIFICATION TEST - VER 1. No → Go To 3 849 POWER DOORS - LIFTGATE |