Symptom: PASSENGER SEAT SENSOR FLUID LEVEL TOO LOW When Monitored and Set Condition: PASSENGER SEAT SENSOR FLUID LEVEL TOO LOW When Monitored: With the ignition on, the module performs internal tests on the input signal from the Bladder assembly. Set Condition: This DTC will set if the input signal from the PS is less than 19 - 30 A/D counts. There is probably a leak if a PS fault is also set POSSIBLE CAUSES OCS - SERVICE REPLACEMENT KIT TEST ACTION APPLICABILITY 1 WARNING: TO AVOID PERSONAL INJURY OR DEATH, TURN THE IGNI- All Repair: Replace the OCS Bladder and Cushion Kit in accordance with 225 AIRBAG |