3. Troubleshooting procedure
Step Description
Yes
No
1
Will the troubleshooting procedure be
implemented?
To Step 2
Troubleshooting
procedure
2
Turn off the ignition switch, unfix
Terminal B of control solenoid valve and
turn on the ignition switch but do not turn
on the engine, measure if there is a 12V
power supply to the fuse.
To Step 4
To Step 3
3
Check if the circuit between the fuse and
the control solenoid valve suffers any of
the following:
Ground fault (Ω stage)
Open circuit (Ω stage)
Short circuit with the power source
(anode): (voltage stage)
Confirm
repair
4
Check if the resistance of the solenoid
valve is 5-50 Ω.
To Step 5
To Step 6
5
Turn off the ignition switch, unfix the
ECM terminal and check if the circuit
between the ECM and the control
solenoid valve suffers any of the
following:
Ground fault (Ω stage)
Open circuit (Ω stage)
Short circuit with the power source
(anode): (voltage stage)
Confirm
repair
To Step 7
6
Replace the control solenoid valve and
confirm the repair.
7
Replace the engine control module and
confirm the repair.
Thirteen. Troubleshooting code – water tank low-speed fan relay
1. Troubleshooting code setup conditions and emergency scheme
P0480 Short circuit between water tank
low-speed fan relay drive circuit and the
power source anode
P0480 Open circuit of water tank low-speed
fan relay drive circuit or its ground fault
Ju
dg
m
en
t
co
nd
iti
on
s
• Duration > 3s
Ju
dg
m
en
t
co
nd
iti
on
s
- Duration > 3s