"P1206-01","Errorpath for filtered energizing time of Cylinder 4- above upper limit of filtered
energizing time "
"P1207-02","Errorpath for filtered energizing time of Cylinder 4- below lower limit of filtered
energizing time "
"P1208-01","Errorpath for filtered energizing time of Cylinder 5- above upper limit of filtered
energizing time "
"P1209-02","Errorpath for filtered energizing time of Cylinder 5- below lower limit of filtered
energizing time "
"P120A-01","Errorpath for filtered energizing time of Cylinder 6- above upper limit of filtered
energizing time "
"P120B-02","Errorpath for filtered energizing time of Cylinder 6- below lower limit of filtered
energizing time "
"P120C-01","Errorpath for energizing time calibration injection of Cylinder 1 - above upper limit
of energizing time"
"P120D-02","Errorpath for energizing time calibration injection of Cylinder 1 - below lower limit
of energizing time"
"P120E-01","Errorpath for energizing time calibration injection of Cylinder 2 - above upper limit
of energizing time"
"P120F-02","Errorpath for energizing time calibration injection of Cylinder 2 - below lower limit
of energizing time"
"P1210-01","Errorpath for energizing time calibration injection of Cylinder 3 - above upper limit
of energizing time"
"P1211-02","Errorpath for energizing time calibration injection of Cylinder 3 - below lower limit
of energizing time"
"P1212-01","Errorpath for energizing time calibration injection of Cylinder 4 - above upper limit
of energizing time"
"P1213-02","Errorpath for energizing time calibration injection of Cylinder 4 - below lower limit
of energizing time"
"P1214-01","Errorpath for energizing time calibration injection of Cylinder 5 - above upper limit
of energizing time"
"P1215-02","Errorpath for energizing time calibration injection of Cylinder 5 - below lower limit
of energizing time"
"P1216-01","Errorpath for energizing time calibration injection of Cylinder 6 - above upper limit
of energizing time"
"P1217-02","Errorpath for energizing time calibration injection of Cylinder 6 - below lower limit
of energizing time"
"P0475-04","fault path for EVCD power stage - No Load "
"P0476-08","fault path for EVCD power stage - Excess Temperature"