Page 38
Lotus Service Notes
Section EMP Fuel Pump P0627 P0627 Fuel Pump Control Circuit /Open Description The fuel system is of the non-return type. The pump is incorporated into the fuel tank module which also con- tains the level sensor, regulator and vapour pressure sensor. Component connections Connector Description ECU Pin ECU Connector 4 (RMC 1 – MFRU*) Inertia Switch (Pin 1) - - 2 (RMC 2 – MFRU*) Fuel Pump Relay 68 (J4) 28 Way (Left) '06 M.Y. in brackets *MFRU – Multi Function Relay Unit Monitor: Continuous Enable Criteria: Ignition on Disable Criteria: None Potential failure modes: • Pump open circuit or short to ground • Multi Function Relay Unit failure • Pump failure • ECU output circuit failure Notes: No MIL will be illuminated for this failure. sn_emp_cyclone.indd 38 03/03/2006 11:03:39 |