Inserting the connectors 1. Push in connectors -B- for DME control module and lock with the latching lever. 2. Press in connectors -A- on the control module they engage. Tightening fastening screws 3. Fasten control module with the four fastening screws -1- to the roll-over protection frame. Subsequent work Subsequent work on DME control unit 1. Place carpet lining in position, paying attention to the fitted shape. 2. The DME control unit can be programmed using the PIWIS Tester 9718. Subsequent work for DME control module in Cabriolet 1. Reinstall the carpet over the motor. 2. The DME control unit can be programmed using the PIWIS Tester 9718. Diagnostic system: reading out fault memory and activating systems Installing DME control module in cabriolet 721 |