DTC P0705 PARK/NEUTRAL POSITION SWITCH CVT-83 D E F G H I J K L M A B CVT Revision: 2004 November 2004 Murano TCM terminals and data are reference values, measured between each terminal and ground. *: Without manual mode Terminal Wire color Item Condition Data (Approx.) 27 BR/W PNP switch 1 Selector lever in “P”, “L”* positions. Battery voltage Selector lever in other positions. 0V 34 P/B PNP switch 2 Selector lever in “P”, “R” positions. 10.0V - Battery Selector lever in other positions. 0V 35 P/L PNP switch 3 Selector lever in “P”, “R”, “N” positions. 8.0V - Battery volt- Selector lever in other positions. 0V 36 G PNP switch 4 Selector lever in “P”, “N”, “L”* positions. 10.0V - Battery Selector lever in other positions. 0V 32 GR PNP switch 3 Selector lever in “P”, “R”, “N” positions. 8.0V - Battery volt- Selector lever in other positions. 0V |