ON-VEHICLE SERVICE BRC-49 [VDC/TCS/ABS] C D E G H I J K L M A B BRC Revision: 2004 November 2004 Murano Calibration of Decel G Sensor AFS001Z7 After removing/installing or replacing Yaw rate/side/decel G sensor, ABS actuator and electric unit (control × : Required –: Not required CAUTION: To calibrate decel G sensor, make sure to use CONSULT- II (Adjustment cannot be done without CON- 1. Stop vehicle with front wheels in straight-ahead position. CAUTION: ● Keep all tires inflated to correct pressures. Adjust the tire ● See that there is on-load in vehicle other than the driver 2. Connect CONSULT- II to data link connector on vehicle, and 3. Touch “ABS”, “WORK SUPPORT” and “DECEL G SEN CALI- 4. Touch “START”. 5. After approximately 10 seconds, touch “END”. (After approxi- 6. Turn ignition switch OFF, then turn it ON again. CAUTION: Be sure to carry out above operation. 7. Run vehicle with front wheels in straight-ahead position, then 8. Select “DATA MONITOR”, “SELECTION FROM MENU”, and ± 0.08G. If value is more than specifi- cation, repeat steps 1 to 5. 9. Erase memory of ABS actuator and electric unit (control unit) and ECM. 10. Turn ignition switch OFF. Situation Calibration of Decel G Sensor Removing/Installing ABS actuator and electric unit (control unit) × Removing/Installing steering components – Removing/Installing suspension components – Change tires to new ones – Tire rotation – Adjusting wheel alignment – Removing/Installing Yaw rate/side/decel G sensor × PBIB1300E LFIA0171E |