SC-30 SERVICE DATA AND SPECIFICATIONS (SDS) Revision; 2004 April 2003 Murano SERVICE DATA AND SPECIFICATIONS (SDS) PFP:00030 Battery AKS004FA Starter AKS004FB Alternator AKS004FC Type 80D23L Capacity 12V - 52AH Cold cranking current (For reference value) 582A Type M1T68681 MITSUBISHI make Reduction gear type System voltage 12V No-load Terminal voltage 11V Current Less than 90A Revolution More than 2,750 rpm Minimum diameter of commutator 28.8 mm (1.134 in) Minimum length of brush 5.5 mm (0.217 in) Brush spring tension 15.0 - 20.4 N (1.53 - 20.8 kg, 3.3 - 4.5 lb) Clearance between bearing metal and armature shaft Less than 0.2 mm (0.008 in) Movement “ ” in height of pinion assembly 0.5 - 2.0 mm (0.020 - 0.079 in) Type LR1110 - 723V HITACHI make Nominal rating 12V - 110A Ground polarity Negative Minimum revolution under no-load (When 13.5V is applied) Less than 1,100 rpm Hot output current (When 13.5V is applied) (More than 35A/1,300rpm) More than 70A/1,800 rpm More than 91A/2,500 rpm More than 110A/5,000 rpm Regulated output voltage 14.1 - 14.7V Minimum length of brush More than 6.00 mm (0.236 in) Brush spring pressure 1.00 - 3.43 N (102 - 350 g, 3.60 - 12.34 oz) Slip ring minimum outer diameter More than 26.0 mm (1.024 in) Rotor (Field coil) resistance 2.16 - 2.45 Ω |