EXL-70

< DTC/CIRCUIT DIAGNOSIS >

[XENON TYPE]

FRONT FOG LAMP CIRCUIT

Is the inspection result normal?

YES

>> GO TO 4.

NO

>> Repair or replace harness.

4.

CHECK FRONT FOG LAMP GROUND CIRCUIT

Check continuity between front fog lamp harness connector and ground.

Is the inspection result normal?

YES

>> Replace the corresponding front fog lamp bulb. Refer to 

EXL-103, "Replacement"

.

NO

>> Repair or replace harness.

IPDM E/R

Front fog lamp

Continuity

Connector

Terminal

Connector

Terminal

RH

E12

19

E48

1

Existed

LH

20

E30

Front fog lamp

Continuity

Connector

Terminal

RH

E48

2

Ground

Existed

LH

E30

Revision: November 2015

2016 JUKE

TURN SIGNAL LAMP CIRCUIT

EXL-71

< DTC/CIRCUIT DIAGNOSIS >

[XENON TYPE]

C

D

E

F

G

H

I

J

K

M

A

B

EXL

N

O

P

TURN SIGNAL LAMP CIRCUIT

Component Function Check

INFOID:0000000012201657

1.

CHECK TURN SIGNAL LAMP OPERATION

With CONSULT

1. Turn ignition switch ON.

2. Select “FLASHER” of “BCM” using CONSULT.

3. Select “FLASHER” in “Active Test” mode.

4. With operating the test items, check that the turn signal lamps is turned ON.

Is the inspection result normal?

YES

>> Turn signal lamp circuit is normal.

NO

>> Refer to 

EXL-71, "Diagnosis Procedure"

.

Diagnosis Procedure

INFOID:0000000012201658

1.

CHECK TURN SIGNAL LAMP POWER SUPPLY

With CONSULT

1. Turn ignition switch OFF.

2. Disconnect the following connectors.

-

Front turn signal lamp

-

Door mirror

-

Rear combination lamp

3. Turn ignition switch ON.

4. Select “FLASHER” of “BCM” using CONSULT.

5. Select “FLASHER” in “Active Test” mode.

6. With operating the test items, check voltage between BCM harness connector and ground.

Is the inspection result normal?

YES

>> GO TO 3.

NO

>> GO TO 2.

2.

CHECK TURN SIGNAL LAMP POWER SUPPLY CIRCUIT (SHORT)

1. Turn ignition switch OFF.

2. Disconnect BCM connector.

3. Check continuity between BCM harness connector and ground.

Is the inspection result normal?

RH

: Turn signal lamps (RH) ON

LH

: Turn signal lamps (LH) ON

Off

: Turn signal lamps OFF

+

-

Test item

Voltage

BCM

Connector

Terminal

RH

M69

61

Ground

FLASHER

RH

9 – 16 V

Off

0 V

LH

60

LH

9 – 16 V

Off

0 V

BCM

Continuity

Connector

Terminal

RH

M69

61

Ground

Not existed

LH

60

Revision: November 2015

2016 JUKE

EXL-72

< DTC/CIRCUIT DIAGNOSIS >

[XENON TYPE]

TURN SIGNAL LAMP CIRCUIT

YES

>> Replace BCM. Refer to 

BCS-94, "Removal and Installation"

.

NO

>> Repair or replace harness.

3.

CHECK TURN SIGNAL LAMP POWER SUPPLY CIRCUIT (OPEN)

1. Turn ignition switch OFF.

2. Disconnect BCM connector.

3. Check continuity between BCM harness connector and each turn signal lamp harness connector.

Front turn signal lamp

Side turn signal lamp

Rear turn signal lamp

Is the inspection result normal?

YES

>> GO TO 4.

NO

>> Repair or replace harness.

4.

CHECK TURN SIGNAL LAMP GROUND CIRCUIT

Check continuity between each turn signal lamp harness connector and ground.

Front turn signal lamp

Side turn signal lamp

Rear turn signal lamp

Is the inspection result normal?

YES-1 >> Front turn signal lamp or rear turn signal lamp: GO TO 5.

YES-2 >> Side turn signal lamp: Replace the corresponding side turn signal lamp. Refer to 

EXL-104,

"Removal and Installation"

.

NO

>> Repair or replace harness.

BCM

Front turn signal lamp

Continuity

Connector

Terminal

Connector

Terminal

 RH

M69

61

E47

1

Existed

 LH

60

E34

BCM

Door mirror

Continuity

Connector

Terminal

Connector

Terminal

 RH

M69

61

D9

13

Existed

 LH

60

D30

BCM

Rear combination lamp

Continuity

Connector

Terminal

Connector

Terminal

 RH

M69

61

B59

5

Existed

 LH

60

B80

Front turn signal lamp

Continuity

Connector

Terminal

RH

E47

2

Ground

Existed

LH

E34

Door mirror

Continuity

Connector

Terminal

RH

D9

2

Ground

Existed

LH

D30

Rear combination lamp

Continuity

Connector

Terminal

RH

B59

3

Ground

Existed

LH

B80

Revision: November 2015

2016 JUKE

TURN SIGNAL LAMP CIRCUIT

EXL-73

< DTC/CIRCUIT DIAGNOSIS >

[XENON TYPE]

C

D

E

F

G

H

I

J

K

M

A

B

EXL

N

O

P

5.

CHECK TURN SIGNAL LAMP BULB

Check the applicable turn signal lamp bulb.
Is the inspection result normal?

YES-1 >> Front turn signal lamp: Check the corresponding front turn signal lamp bulb socket. Repair or

replace if necessary.

YES-2 >> Rear turn signal lamp: Check the corresponding rear turn signal lamp bulb socket and harness.

Repair or replace if necessary.

NO

>> Replace the corresponding turn signal lamp bulb. Refer to 

EXL-100, "Replacement"

 (front turn

signal lamp) or 

EXL-109, "Replacement"

 (rear turn signal lamp).

Revision: November 2015

2016 JUKE

EXL-74

< DTC/CIRCUIT DIAGNOSIS >

[XENON TYPE]

OPTICAL SENSOR

OPTICAL SENSOR

Component Function Check

INFOID:0000000012201659

1.

CHECK OPTICAL SENSOR SIGNAL

With CONSULT

1. Turn ignition switch ON.

2. Select “HEAD LAMP” of “BCM” using CONSULT.

3. Select “OPTI SEN (DTCT)” in “Data Monitor” mode.

4. Turn lighting switch AUTO.

5. With the optical sensor illuminating, check the monitor status. 

*: Illuminates the optical sensor. The value may be less than the standard value if brightness is weak.
Is the inspection result normal?

YES

>> Optical sensor is normal.

NO

>> Refer to 

EXL-74, "Diagnosis Procedure"

.

Diagnosis Procedure

INFOID:0000000012201660

1.

CHECK OPTICAL SENSOR POWER SUPPLY

1. Turn ignition switch ON.

2. Turn lighting switch AUTO.

3. Check voltage between optical sensor harness connector and ground.

Is the inspection result normal?

YES

>> GO TO 2.

NO

>> GO TO 4.

2.

CHECK OPTICAL SENSOR GROUND

Check voltage between optical sensor harness connector and ground.

Is the inspection result normal?

YES

>> GO TO 3.

NO

>> GO TO 6.

3.

CHECK OPTICAL SENSOR SIGNAL

 With illuminating the optical sensor, check voltage between optical sensor harness connector and ground.

Monitor item

Condition

Voltage

(Approx.)

OPTI SEN (DTCT) Optical sensor

When illuminating

3.1 V or more *

When shutting off light

0.6 V or less

+

-

Voltage

(Approx.)

Optical sensor

Connector

Terminal

M84

1

Ground

5 V

+

-

Voltage

(Approx.)

Optical sensor

Connector

Terminal

M84

3

Ground

0 V

Revision: November 2015

2016 JUKE

OPTICAL SENSOR

EXL-75

< DTC/CIRCUIT DIAGNOSIS >

[XENON TYPE]

C

D

E

F

G

H

I

J

K

M

A

B

EXL

N

O

P

*: Illuminate the optical sensor. The value may be less than the standard if brightness is weak.
Is the inspection result normal?

YES

>> GO TO 7.

NO

>> Replace optical sensor. Refer to 

EXL-105, "Removal and Installation"

.

4.

CHECK OPTICAL SENSOR POWER SUPPLY CIRCUIT (OPEN)

1. Turn ignition switch OFF.

2. Disconnect optical sensor connector and BCM connector.

3. Check continuity between optical sensor harness connector and BCM harness connector.

Is the inspection result normal?

YES

>> GO TO 5.

NO

>> Repair or replace harness.

5.

CHECK OPTICAL SENSOR POWER SUPPLY CIRCUIT (SHORT)

Check continuity between optical sensor harness connector and ground.

Is the inspection result normal?

YES

>> Replace BCM. Refer to 

BCS-94, "Removal and Installation"

.

NO

>> Repair or replace harness.

6.

CHECK OPTICAL SENSOR GROUND CIRCUIT

1. Turn ignition switch OFF.

2. Disconnect optical sensor connector and BCM connector.

3. Check continuity between optical sensor harness connector and BCM harness connector.

Is the inspection result normal?

YES

>> Replace BCM. Refer to 

BCS-94, "Removal and Installation"

.

NO

>> Repair or replace harness.

7.

CHECK OPTICAL SENSOR SIGNAL CIRCUIT (OPEN) 

1. Turn ignition switch OFF.

2. Disconnect optical sensor connector and BCM connector.

3. Check continuity between optical sensor harness connector and BCM harness connector.

+

-

Condition

Voltage

(Approx.)

Optical sensor

Connector

Terminal

M84

2

Ground

Optical sensor

When illuminating

3.1 V or more*

When shutting off light

0.6 V or less

Optical sensor

BCM

Continuity

Connector

Terminal

Connector

Terminal

M84

1

M68

17

Existed

Optical sensor

Continuity

Connector

Terminal

M84

1

Ground

Not existed

Optical sensor

BCM

Continuity

Connector

Terminal

Connector

Terminal

M84

3

M68

18

Existed

Revision: November 2015

2016 JUKE

EXL-76

< DTC/CIRCUIT DIAGNOSIS >

[XENON TYPE]

OPTICAL SENSOR

Is the inspection result normal?

YES

>> GO TO 8.

NO

>> Repair or replace harness.

8.

CHECK OPTICAL SENSOR SIGNAL CIRCUIT (SHORT)

Check continuity between optical sensor harness connector and ground.

Is the inspection result normal?

YES

>> Replace BCM. Refer to 

BCS-94, "Removal and Installation"

.

NO

>> Repair or replace harness.

Optical sensor

BCM

Continuity

Connector

Terminal

Connector

Terminal

M84

2

M68

14

Existed

Optical sensor

Continuity

Connector

Terminal

M84

2

Ground

Not existed

Revision: November 2015

2016 JUKE

HAZARD SWITCH

EXL-77

< DTC/CIRCUIT DIAGNOSIS >

[XENON TYPE]

C

D

E

F

G

H

I

J

K

M

A

B

EXL

N

O

P

HAZARD SWITCH

Component Function Check

INFOID:0000000012201661

1.

CHECK HAZARD SWITCH SIGNAL

With CONSULT

1. Turn ignition switch ON.

2. Select “FLASHER” of “BCM” using CONSULT.

3. Select “HAZARD SW” in “Data Monitor” mode.

4. With operating the hazard switch, check the monitor status.

Is the inspection result normal?

YES

>> Hazard switch circuit is normal.

NO

>> Refer to 

EXL-77, "Diagnosis Procedure"

.

Diagnosis Procedure

INFOID:0000000012201662

1.

CHECK HAZARD SWITCH SIGNAL

1. Turn ignition switch OFF.

2. Disconnect hazard switch connector.

3. Check voltage between hazard switch connector and ground.

Is the inspection result normal?

YES

>> GO TO 4.

NO

>> GO TO 2.

2.

CHECK HAZARD SWITCH SIGNAL CIRCUIT (OPEN)

1. Disconnect BCM connector.

2. Check continuity between hazard switch harness connector and BCM harness connector.

Is the inspection result normal?

YES

>> GO TO 3.

NO

>> Repair or replace harness.

3.

CHECK HAZARD SWITCH SIGNAL CIRCUIT (SHORT)

Check continuity between hazard switch harness connector and ground.

Is the inspection result normal?

YES

>> Replace BCM. Refer to 

BCS-94, "Removal and Installation"

.

Monitor item

Condition

Monitor status

HAZARD SW

Hazard switch

ON

On

OFF

Off

+

-

Voltage

(Approx.)

Hazard switch

Connector

Terminal

M45

2

Ground

12 V

Hazard switch

BCM

Continuity

Connector

Terminal

Connector

Terminal

M45

2

M68

29

Existed

Hazard switch

Continuity

Connector

Terminal

M45

2

Ground

Not existed

Revision: November 2015