|
|
P0452 EVAP CONTROL SYSTEM PRESSURE SENSOR EC-921 < DTC/CIRCUIT DIAGNOSIS > [VK50VE] C D E F G H I J K L M A EC N P O >> INSPECTION END 10. CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR GROUND CIRCUIT FOR OPEN AND SHORT 1. Turn ignition switch OFF. 2. Disconnect ECM harness connector. 3. Check the continuity between EVAP control system pressure sensor harness connector and ECM har- 4. Also check harness for short to ground and short to power. Is the inspection result normal? YES >> GO TO 12. NO >> GO TO 11. 11. DETECT MALFUNCTIONING PART Check the following. >> Repair open circuit, short to ground or short to power in harness or connectors. 12. CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR INPUT SIGNAL CIRCUIT FOR OPEN AND SHORT 1. Check the continuity between EVAP control system pressure sensor harness connector and ECM har- 2. Also check harness for short to ground and short to power. Is the inspection result normal? YES >> GO TO 14. NO >> GO TO 13. 13. DETECT MALFUNCTIONING PART Check the following. >> Repair open circuit, short to ground or short to power in harness or connectors. 14. CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR EC-922, "Component Inspection" Is the inspection result normal? YES >> GO TO 15. NO >> Replace EVAP control system pressure sensor. EVAP control system pressure sensor ECM Continuity Connector Terminal Connector Terminal B252 1 F111 70 Existed EVAP control system pressure sensor ECM Continuity Connector Terminal Connector Terminal B252 2 F111 80 Existed |