Infiniti FX35, FX50 (S51). Manual - part 845

 

  Index      Infiniti     Infiniti FX35, FX50 (S51) - service repair manual 2010 year

 

Search            

 

 

 

 

 

 

 

 

 

Content   ..  843  844  845  846   ..

 

 

Infiniti FX35, FX50 (S51). Manual - part 845

 

 

P0452 EVAP CONTROL SYSTEM PRESSURE SENSOR

EC-921

< DTC/CIRCUIT DIAGNOSIS >

[VK50VE]

C

D

E

F

G

H

I

J

K

L

M

A

EC

N

P

O

>> INSPECTION END

10.

CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR GROUND CIRCUIT FOR OPEN AND

SHORT

1.

Turn ignition switch OFF.

2.

Disconnect ECM harness connector.

3.

Check the continuity between EVAP control system pressure sensor harness connector and ECM har-
ness connector.

4.

Also check harness for short to ground and short to power.

Is the inspection result normal?

YES

>> GO TO 12.

NO

>> GO TO 11.

11.

DETECT MALFUNCTIONING PART

Check the following.
• Harness connectors B201, M117
• Harness connectors M116, F103
• Harness for open or short between EVAP control system pressure sensor and ECM

>> Repair open circuit, short to ground or short to power in harness or connectors.

12.

CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR INPUT SIGNAL CIRCUIT FOR OPEN AND

SHORT

1.

Check the continuity between EVAP control system pressure sensor harness connector and ECM har-
ness connector.

2.

Also check harness for short to ground and short to power.

Is the inspection result normal?

YES

>> GO TO 14.

NO

>> GO TO 13.

13.

DETECT MALFUNCTIONING PART

Check the following.
• Harness connectors B201, M117
• Harness connectors M116, F103
• Harness for open or short between EVAP control system pressure sensor and ECM

>> Repair open circuit, short to ground or short to power in harness or connectors.

14.

CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR

Refer to 

EC-922, "Component Inspection"

.

Is the inspection result normal?

YES

>> GO TO 15.

NO

>> Replace EVAP control system pressure sensor.

EVAP control system 

pressure sensor

ECM

Continuity

Connector

Terminal

Connector

Terminal

B252

1

F111

70

Existed

EVAP control system 

pressure sensor

ECM

Continuity

Connector

Terminal

Connector

Terminal

B252

2

F111

80

Existed

EC-922

< DTC/CIRCUIT DIAGNOSIS >

[VK50VE]

P0452 EVAP CONTROL SYSTEM PRESSURE SENSOR

15.

CHECK INTERMITTENT INCIDENT

Refer to 

GI-36, "Intermittent Incident"

.

>> INSPECTION END

Component Inspection

INFOID:0000000005237391

1.

CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR

1.

Turn ignition switch OFF.

2.

Remove EVAP control system pressure sensor with its harness connector.
Always replace O-ring with a new one.

3.

Install a vacuum pump to EVAP control system pressure sensor.

4.

Turn ignition switch ON and check output voltage between ECM harness connector terminals under the
following conditions.

CAUTION:

• Always calibrate the vacuum pump gauge when using it.
• Never apply below -93.3 kPa (-0.952 kg/cm

2

, -13.53 psi) or pressure over 101.3 kPa (1.033 kg/cm

2

,

14.69 psi).

Is the inspection result normal?

YES

>> INSPECTION END

NO

>> Replace EVAP control system pressure sensor.

ECM

Condition

[Applied vacuum kPa (kg/cm

2

, psi)]

Voltage (V)

Connector

+

Terminal

Terminal

F111

80

70

Not applied

1.8 - 4.8

-26.7 (-0.272, -3.87)

2.1 to 2.5 lower than above value

P0453 EVAP CONTROL SYSTEM PRESSURE SENSOR

EC-923

< DTC/CIRCUIT DIAGNOSIS >

[VK50VE]

C

D

E

F

G

H

I

J

K

L

M

A

EC

N

P

O

P0453 EVAP CONTROL SYSTEM PRESSURE SENSOR

Description

INFOID:0000000005237392

The EVAP control system pressure sensor detects pressure in the
purge line. The sensor output voltage to the ECM increases as pres-
sure increases.

DTC Logic

INFOID:0000000005237393

DTC DETECTION LOGIC

DTC CONFIRMATION PROCEDURE

1.

PRECONDITIONING

If DTC Confirmation Procedure has been previously conducted, always perform the following procedure
before conducting the next test. 
1.

Turn ignition switch OFF and wait at least 10 seconds.

2.

Turn ignition switch ON.

3.

Turn ignition switch OFF and wait at least 10 seconds.

TESTING CONDITION:
Always perform test at a temperature of 5

°

C (41

°

F) or more.

>> GO TO 2.

2.

PERFORM DTC CONFIRMATION PROCEDURE

 With CONSULT-III

1.

Start engine and warm it up to normal operating temperature.

2.

Turn ignition switch OFF and wait at least 10 seconds.

3.

Turn ignition switch ON.

PBIB3370E

DTC No.

Trouble diagnosis name

DTC detecting condition

Possible cause

P0453

EVAP control system 
pressure sensor high in-
put

An excessively high voltage from 
the sensor is sent to ECM.

• Harness or connectors

(EVAP control system pressure sensor circuit is open 
or shorted.)
(APP sensor 2 circuit is shorted.)
(Battery current sensor circuit is shorted.)
[Camshaft position sensor (bank 1) circuit is shorted.]
[Crankshaft position sensor circuit is shorted.]
[Exhaust valve timing control position sensor (bank 1) 
circuit is shorted.]
(Manifold absolute pressure sensor circuit is shorted.)

• EVAP control system pressure sensor
• Accelerator pedal position sensor
• Battery current sensor
• Camshaft position sensor (bank 1)
• Crankshaft position sensor
• Exhaust valve timing control position sensor (bank 1)
• Manifold absolute pressure sensor
• EVAP canister vent control valve
• EVAP canister
• Rubber hose from EVAP canister vent control valve to 

vehicle frame

EC-924

< DTC/CIRCUIT DIAGNOSIS >

[VK50VE]

P0453 EVAP CONTROL SYSTEM PRESSURE SENSOR

4.

Turn ignition switch OFF and wait at least 10 seconds.

5.

Turn ignition switch ON.

6.

Select “DATA MONITOR” mode with CONSULT-III.

7.

Check that “FUEL T/TMP SE” is more than 0

°

C (32

°

F).

8.

Start engine and wait at least 20 seconds.

9.

Check 1st trip DTC.

 With GST

1.

Start engine and warm it up to normal operating temperature.

2.

Set voltmeter probes to ECM harness connector terminals under the following conditions.

3.

Check that the voltage is less than 4.2 V.

4.

Turn ignition switch OFF and wait at least 10 seconds.

5.

Turn ignition switch ON.

6.

Turn ignition switch OFF and wait at least 10 seconds.

7.

Start engine and wait at least 20 seconds.

8.

Check 1st trip DTC.

Is 1st trip DTC detected?

YES

>> Go to 

EC-924, "Diagnosis Procedure"

.

NO

>> INSPECTION END

Diagnosis Procedure

INFOID:0000000005237394

1.

CHECK GROUND CONNECTION

1.

Turn ignition switch OFF.

2.

Check ground connection M95. Refer to Ground Inspection in 

GI-39, "Circuit Inspection"

.

Is the inspection result normal?

YES

>> GO TO 2.

NO

>> Repair or replace ground connection.

2.

CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR CONNECTOR

1.

Disconnect EVAP control system pressure sensor harness connector.

2.

Check that water is not inside connectors.

Is the inspection result normal?

YES

>> GO TO 3.

NO

>> Repair or replace harness connector.

3.

CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR POWER SUPPLY CIRCUIT

1.

Turn ignition switch ON.

2.

Check the voltage between EVAP control system pressure sensor harness connector and ground.

Is the inspection result normal?

YES

>> GO TO 10.

NO

>> GO TO 4.

4.

CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR POWER SUPPLY CIRCUIT-II

1.

Turn ignition switch OFF.

2.

Disconnect ECM harness connector.

ECM

Ground

Connector

+

Terminal

Terminal

M160

120

(Fuel tank temperature sensor signal)

128

EVAP control system pressure sensor

Ground

Voltage (V)

Connector

Terminal

B252

3

Ground

Approx. 5

 

 

 

 

 

 

 

Content   ..  843  844  845  846   ..