P0037, P0038, P0057, P0058 HO2S2 HEATER EC-765 < DTC/CIRCUIT DIAGNOSIS > [VK50VE] C D E F G H I J K L M A EC N P O YES >> GO TO 5. NO >> Repair open circuit, short to ground or short to power in harness or connectors. 5. CHECK HO2S2 HEATER EC-765, "Component Inspection" Is the inspection result normal? YES >> GO TO 7. NO >> GO TO 6. 6. REPLACE HEATED OXYGEN SENSOR 2 Replace malfunctioning heated oxygen sensor 2. CAUTION: • Discard any heated oxygen sensor which has been dropped from a height of more than 0.5 m (19.7 in) onto a hard surface such as a concrete floor; use a new one. • Before installing new oxygen sensor, clean exhaust system threads using Oxygen Sensor Thread Cleaner [commercial service tool (J-43897-18 or J-43897-12)] and approved anti-seize lubricant >> INSPECTION END 7. CHECK INTERMITTENT INCIDENT GI-36, "Intermittent Incident" . >> INSPECTION END Component Inspection INFOID:0000000005237245 1. CHECK HEATED OXYGEN SENSOR 2 HEATER 1. Turn ignition switch OFF. 2. Disconnect heated oxygen sensor 2 (HO2S2) harness connector. 3. Check resistance between HO2S2 terminals as follows. Is the inspection result normal? YES >> INSPECTION END NO >> GO TO 2. 2. REPLACE HEATED OXYGEN SENSOR 2 Replace malfunctioning heated oxygen sensor 2. CAUTION: • Discard any heated oxygen sensor which has been dropped from a height of more than 0.5 m (19.7 in) onto a hard surface such as a concrete floor; use a new one. • Before installing new oxygen sensor, clean exhaust system threads using Oxygen Sensor Thread Cleaner [commercial service tool (J-43897-18 or J-43897-12)] and approved anti-seize lubricant >> INSPECTION END Terminal Resistance 2 and 3 3.4 - 4.4 Ω [at 25 ° C (77 ° F)] 1 and 2, 3, 4 ∞
Ω (Continuity should not exist) 4 and 1, 2, 3 |